WAGO 852 Series Скачать руководство пользователя страница 1

 

 

 

Manual 

WAGO ETHERNET Accessories 852 

 

 

 

852-111  

Industrial ECO Switch 

5 Ports 100BASE-TX 

Version 1.3.1  

 

 

 

Содержание 852 Series

Страница 1: ...Manual WAGO ETHERNET Accessories 852 852 111 Industrial ECO Switch 5 Ports 100BASE TX Version 1 3 1 ...

Страница 2: ...4 45 55 E Mail support wago com Every conceivable measure has been taken to ensure the accuracy and completeness of this documentation However as errors can never be fully excluded we always appreciate any information or suggestions for improving the documentation E Mail documentation wago com We wish to point out that the software and hardware terms as well as the trademarks of companies used and...

Страница 3: ... 11 2 3 Special Use Conditions for ETHERNET Devices 13 3 General 14 3 1 Scope of Supply 14 3 2 Industrial ETHERNET Technology 14 3 3 Switching Technology 14 3 4 Autonegotiation 14 3 5 Functioning of Switches 15 3 6 Port Speed Duplex Mode 15 4 Device Description 16 4 1 View 17 4 1 1 Front View 17 4 1 2 Top View 18 4 2 Connectors 19 4 2 1 Grounding screw 19 4 2 2 Power Supply PWR 19 4 2 3 Network Co...

Страница 4: ...852 852 111 Industrial ECO Switch Manual Version 1 3 1 5 4 Screw Mounting 26 6 Connect Devices 27 6 1 Power Supply 27 7 Accessories 28 8 Appendix 29 8 1 RJ 45 Cable 29 8 2 Drilling Template for Screw Mounting 31 List of Figures 33 List of Tables 34 ...

Страница 5: ...sary 1 1 Validity of this Documentation This documentation is only applicable to WAGO ETHERNET accessory products Industrial ECO Switch 852 111 This documentation is only applicable from 1 2 Copyright This Manual including all figures and illustrations is copyright protected Any further use of this Manual by third parties that violate pertinent copyright provisions is prohibited Reproduction trans...

Страница 6: ...icates a moderate risk potentially hazardous situation which if not avoided could result in death or serious injury Personal Injury Indicates a low risk potentially hazardous situation which if not avoided may result in minor or moderate injury Damage to Property Indicates a potentially hazardous situation which if not avoided may result in damage to property Damage to Property Caused by Electrost...

Страница 7: ...ssories 852 Notes about this Documentation 7 852 111 Industrial ECO Switch Manual Version 1 3 1 Additional Information Refers to additional information which is not an integral part of this documentation e g the Internet ...

Страница 8: ...ata files are marked in italic type e g C Program Files WAGO Software Menu Menu items are marked in bold letters e g Save A greater than sign between two names means the selection of a menu item from a menu e g File New Input Designation of input or optional fields are marked in bold letters e g Start of measurement range Value Input or selective values are marked in inverted commas e g Enter the ...

Страница 9: ...party products are always mentioned without any reference to patent rights Thus the existence of such rights cannot be excluded 2 1 2 Personnel Qualification All sequences implemented on Series 852 devices may only be carried out by electrical specialists with sufficient knowledge in automation The specialists must be familiar with the current norms and guidelines for the devices and automated env...

Страница 10: ...rating the Industrial Switches Please observe the standards and regulations that are relevant to installation The data and power lines must be connected and installed in compliance with the standards to avoid failures on your installation and eliminate any danger to personnel For installation startup maintenance and repair please observe the accident prevention regulations of your machine e g DGUV...

Страница 11: ...these switches in lockable housings cabinets or electrical operation rooms Access must be limited to authorized qualified staff having the appropriate key or tool Ensure a standard connection To minimize any hazardous situations resulting in personal injury or to avoid failures in your system the data and power supply lines shall be installed according to standards with careful attention given to ...

Страница 12: ...e for handling devices modules Clean only with permitted materials Clean housing and soiled contacts with propanol Do not use any contact spray Do not use any contact spray The spray may impair contact area functionality in connection with contamination Do not reverse the polarity of connection lines Avoid reverse polarity of data and power supply lines as this may damage the devices involved Avoi...

Страница 13: ...orks behind a firewall Limit physical and electronic access to all automation components to authorized personnel only Change the default passwords before first use This will reduce the risk of unauthorized access to your system Regularly change the passwords used This will reduce the risk of unauthorized access to your system If remote access to control components and control networks is required ...

Страница 14: ...THERNET primarily uses switching technology This technology allows any network subscriber to send at any time because the subscriber always has an open peer to peer connection to the next switch The connection is bidirectional i e the subscriber can send and receive at the same time full duplex The targeted use of switching technology can increase real time capability because the peer to peer conn...

Страница 15: ...ly by the switch through a self learning process Incoming data packages are analyzed filtered and forwarded directly to the appropriate port by using this assignment table based on their destination address The incoming data package is sent to all ports if there is no corresponding entry in the assignment table for a destination address If a destination address answers the assignment table is comp...

Страница 16: ...ctive solution to keep up with the constant demands for emerging IP based industry communication needs The switch can be easily configured and installed and is also ideally suited for small to medium sized networks Other key features are Five 5 10 100BASE TX Ports Comprehensive front panel diagnostic LEDs Supports Auto MDI MDI X Full half duplex transfer modes for each port Wide supply voltage ran...

Страница 17: ...ial ECO Switch Table 3 Legend for Figure Front View of Industrial ECO Switch Pos Descrip tion Meaning Details see Section 1 Status LED TX Port 100 Mbit s 1 LED for each port Device Description Display Elements 2 Status LED T Port LNK ACT 1 LED for each port Device Description Display Elements 3 Port 5 x RJ 45 10 100BASE TX Ports Device Description Connectors ...

Страница 18: ...f the Industrial ECO Switch Table 4 Legend for Figure Top View of the Industrial ECO Switch Pos Descrip tion Meaning Details see Section 1 Terminal block male connector for power supply PWR Device Description Connectors 2 PWR Status LED Power Supply Device Description Display Elements 3 Grounding screw Device Description Grounding screw ...

Страница 19: ...he 3 pole male connector located on the top of the ECO switch The male connector shows the following pin assignment Figure 4 Power supply PWR port Table 5 Legend for Power supply PWR port figure Pin Description Description PWR Primary DC input PWR Primary DC input GND Ground potential functional earth Damage to Property Caused by Electrostatic Discharge ESD Industrial ECO switch for DC operation P...

Страница 20: ...gure 5 10 100BASE TX The 10 100BASE TX ports support network speeds of either 10 Mbit s or 100 Mbit s and can operate in half and full duplex transfer modes The ports also offer automatic MDI MDI X crossover detection that gives true plug and play capability just plug the network cables into the ports and the ports will adjust according to the end node devices The following are the recommended cab...

Страница 21: ... You can see the status of the industrial ECO switch at a quick glance of the power supply LED while the network LEDs provide information about the connection actions 4 3 1 Power Supply LED Figure 6 Power supply LED Table 6 Legend for Power supply LED figure LED Name Status Description PWR Primary Power LED Green The industrial ECO switch uses the primary power supply OFF The primary power supply ...

Страница 22: ... Status Description 100 100BASE TX Port LED 1 LED for each port Green Port operating at 100 Mbit s Flashing Data traffic being routed over the port OFF Connection in operation at less than 100 Mbit s LNK ACT LNK ACT Port LED 1 LED for each port Green Illuminated when connectors are attached 1 LED for each port Flashing Data traffic passing through port OFF No valid link established on port ...

Страница 23: ...the top edge of the carrier rail Length Wall mounting 109 2 mm Carrier rail mounting 109 2 mm Weight 145 g Mounting Wall mounting horizontal or vertical or mounting on a carrier rail Degree of protection IP30 4 4 2 Power Supply Table 9 Technical Data Power Supply Supply voltage 18 30 VDC Power consumption max 3 W 4 4 3 Communication Table 10 Technical Data Communication Ports 5 x 10 100BASE TX RJ ...

Страница 24: ...NV GL Temperature class D 25 70 C Surrounding air temperature storage 40 80 C UL 508 Use Pollution degree Indoor 2 Relative humidity without condensation 5 95 Vibration resistance Acc to IEC 60068 2 6 Shock resistance Acc to IEC 60068 2 27 EMC 1 immunity to interference Acc to EN 61000 6 2 EMC 1 Emission of interference Acc to EN 61000 6 4 Standard Compass Safe Distance 0 3 Degree deflection 1000 ...

Страница 25: ...itch 852 111 Conformity Marking UL508 E175199 The following ship approvals have been granted for the WAGO ETHERNET accessory product Industrial ECO Switch 852 111 DNV GL Temperature D Humidity B Vibration C EMC B Enclosure A The DNV GL Marine Type Approval is only valid if using the 852 9101 Carrier Rail Adapter in conjunction with an ETHERNET Switch This adapter is available as an accessory see A...

Страница 26: ...not place any heavy objects on the Industrial Eco Switch 5 2 Installation on a Carrier Rail The carrier rail must optimally support the EMC measures integrated into the system and the shielding of the internal data bus connections Place the Industrial Eco Switch onto the DIN rail from the top and snap it into position 5 3 Removal from Carrier Rail To remove the Industrial Eco Switch from the carri...

Страница 27: ... the grounding lug on the top of the switch Ground for the switch The ground for the switch prevents electromagnetic interference from electromagnetic radiation Observe the corresponding standards for EMC compatible installations as well 2 Plug the female connector into the male connector of the switch if it has not already been plugged in Check the tight fit of the multipoint connector by gently ...

Страница 28: ...strial ECO Switch Manual Version 1 3 1 7 Accessories Table 12 Accessories Description Item Number Carrier Rail Adapter 852 9101 The 852 9101 Carrier Rail Adapter is required for Industrial ECO Switch 852 111 installations that comply with the DNV GL standard ...

Страница 29: ...low Table 13 RJ 45 Cable Contact Description Pair Color acc EIA TIA 568B 4 wire 8 wire 1 TD D1 2 White Orange 2 TD D1 2 Orange 3 RX D2 3 White Green 4 Not assigned D3 1 Blue 5 Not assigned D3 1 White Blue 6 RX D2 3 Green 7 Not assigned D4 4 White Brown 8 Not assigned D4 4 Brown Functions on the RJ45 connector The industrial ECO switch offers the functions autocrossing und autonegotiation to the RJ...

Страница 30: ...30 Appendix WAGO ETHERNET Accessories 852 852 111 Industrial ECO Switch Manual Version 1 3 1 ...

Страница 31: ...witch Manual Version 1 3 1 8 2 Drilling Template for Screw Mounting The industrial ECO switch can be mounted vertically or horizontally using the boreholes on the side of the device Use the drilling template shown below to mark the boreholes Figure 8 Drilling template ...

Страница 32: ...32 Appendix WAGO ETHERNET Accessories 852 852 111 Industrial ECO Switch Manual Version 1 3 1 ...

Страница 33: ...n 1 3 1 List of Figures Figure 1 Front View of Industrial ECO Switch 17 Figure 2 Top View of the Industrial ECO Switch 18 Figure 3 Grounding screw 19 Figure 4 Power supply PWR port 19 Figure 5 10 100BASE TX 20 Figure 6 Power supply LED 21 Figure 7 Network LEDs 22 Figure 8 Drilling template 31 ...

Страница 34: ...h 17 Table 4 Legend for Figure Top View of the Industrial ECO Switch 18 Table 5 Legend for Power supply PWR port figure 19 Table 6 Legend for Power supply LED figure 21 Table 7 Legend for Network LEDs figure 22 Table 8 Technical Data Device Data 23 Table 9 Technical Data Power Supply 23 Table 10 Technical Data Communication 23 Table 11 Technical data environmental conditions 24 Table 12 Accessorie...

Страница 35: ...WAGO ETHERNET Accessories 852 35 852 111 Industrial ECO Switch Manual Version 1 3 1 ...

Страница 36: ...WAGO Kontakttechnik GmbH Co KG Postfach 2880 D 32385 Minden Hansastraße 27 D 32423 Minden Phone 49 571 887 0 Fax 49 571 887 844169 E Mail info wago com Internet www wago com ...

Отзывы: