852-1328
Configuration in the WBM
Product manual | Version: 1.2.0
57
Industrial Managed Switch
dustrial managed switch and/or it can be sent to a remote log server. The user needs to
select the log level and provides the IP address of a remote log server and the service
port of the log server. Please click on the
[Submit]
button after finishing the setup. Table
“WBM “Diagnostics” Page – “System Log” – “Setting” Tab” summarizes the descriptions
of the Syslog Settings‘ parameters.
Figure 41: WBM “Diagnostics” Page – “System Log” – “Setting” Tab
Table 29: WBM “Diagnostics” Page – “System Log” – “Setting” Tab
Parameters
Factory Default
Description
Enable Log Event to
Flash
Uncheck
Checked:
Saving log event into flash memory. The flash memory
can keep the log event files even if the switch is rebooted.
Unchecked:
Saving log event into RAM memory. The RAM mem-
ory cannot keep the log event files after each reboot.
Log Level (Protokoll-
ebene)
3: (LOG_ERR)
Set the log level to determine what events to be displayed on the
next webpage (Log). The level selection is inclusive. For example,
if 3: (Log_ERR) is selected, all 0, 1, 2 and 3 log levels will be im-
plied.
Range from Log 0 to Log 7.
Enable Syslog
Server
Uncheck
Checked:
Enable Syslog Server.
Uncheck:
Disable Syslog Server.
If enabled, all recorded log events will be sent to the remote Sys-
tem Log server.
Syslog Server IP
0.0.0.0
Set the IP address of Syslog server.
Syslog Server Ser-
vice Port
514
Set the service port number of Syslog server.
Range from Port 1 to Port 65535.