852-1305 8/4-Port 100BASE-T/1000BASE-SX/LX
Manual
1.1.0
DIP switches let the user manually turn ON/OFF any port, the external alarm, or
the redundant power supply.
The DIP switch must be “ON” to activate the port alarm function. The default
setting is “OFF”.
The following is the recommended procedure for configuring and setting DIP
switches during initial installation:
1
Turn all DIP switches to “OFF”.
2
Install the industrial managed switch in your network.
3
Select the port(s) to be monitored or the alarm to be activated.
4
Set the DIP switch of the corresponding port to “ON”.
5
Turn the industrial managed switch ON.
4.4.2
Reset Button
Figure 8: Reset Button
Table 10: Legend for Figure “Reset Button”
Name
Status
Description
Reset
Press the Reset button for 2
seconds and release.
The system is restarted.
Important Note!
Use a suitable object, e.g., ballpoint pen or straightened paper clip, to press the
Reset button.