![WAGO 852-1305 Скачать руководство пользователя страница 196](http://html1.mh-extra.com/html/wago/852-1305/852-1305_manual_3162444196.webp)
196 Configuring in the Web-Based Management System (WBM) WAGO-ETHERNET-Zubehör 852
852-1305 8/4-Port 100BASE-T/1000BASE-SX/LX
Manual
1.1.0
Table 81: WBM “Loop Detection” Page
Loop Detection Settings
Parameters
Default
Description
Status
Disable
Select “Disable” in the selection box to disable this
function.
Enable
Select “Enable” in the selection box to enable this
function.
MAC Address
Enter the destination MAC address in the input field
to which the probe packets should be sent. If the port
receives the same packets, it is shut down.
Port
From:
1
Select a port or port range in the selection box for
which you want to configure the “Loop Guard
Protection” settings.
To:
1
Select a port or port range in the selection box for
which you want to configure the “Loop Guard
Protection” settings.
State
Disable
Select “Disable” in the selection box to disable this
function.
Enable
Select “Enable” in the selection box to enable the
“Loop Guard” function for the switch.
Action
None
Select “None” in the selection box if you disable
loop detection on the port.
Unblock
Select “Unblock” in the selection box if you do not
want to change the “Status” and “Loop Correction”
functions.
Loop Recovery
Enable
Select “Enable” in the selection box to automatically
enable the port again after the designated “Recovery
Time” has elapsed.
Disable
Select “Disable” in the selection box to disable this
function.
Recovery Time (min)
(Range: 1~60)
1
Enter the value for the “Recovery Time” (in
minutes) in the input field that the switch waits
before enabling the port again.
Time: 1 … 60 min
Loop Detection Status
Parameters
Default
Description
Port
1 … 10
This column displays the port numbers.
Status
Enable
Disable
This column displays if the “Loop Guard” function
is enabled or disabled.
Status
None
Normal
This column displays if a port is blocked.
Loop Recovery
Enable
Disable
This column displays if the “Loop Recovery”
function is enabled or disabled.
Recovery Time (min)
1 … 50
This column displays the “Recovery Time” for the
“Loop Recovery” function.