background image

WAGO ETHERNET Accessories 852 

Important Notes 

852-1102 Industrial Switch 

 

 

 

Manual 

 

Version 1.2.0  

 

Important Notes 

 

This section includes an overall summary of the most important safety 

requirements and notes that are mentioned in each individual section. To protect 

your health and prevent damage to devices as well, it is imperative to read and 

carefully follow the safety guidelines. 

 

2.1 

Legal Bases 

 

2.1.1 

Subject to Changes 

WAGO Kontakttechnik GmbH & Co. KG reserves the right to provide for any 

alterations or modifications. WAGO Kontakttechnik GmbH & Co. KG owns all 

rights arising from the granting of patents or from the legal protection of utility 

patents. Third-party products are always mentioned without any reference to 

patent rights. Thus, the existence of such rights cannot be excluded. 

 

2.1.2 

Personnel Qualification 

All sequences implemented on Series 852 devices may only be carried out by 

electrical specialists with sufficient knowledge in automation. The specialists must 

be familiar with the current norms and guidelines for the devices and automated 

environments. 

All changes to the controller should always be carried out by qualified personnel 

with sufficient sufficient skills in PLC programming. 

 

2.1.3 

Proper Use of the Industrial Switches 

The device is designed for the IP30 protection class. It is protected against the 

insertion of solid items and solid impurities up to 2.5 mm in diameter, but not 

against water penetration. Unless otherwise specified, the device must not be 

operated in wet and dusty environments. 

 

2.1.4 

Technical Condition of Specified Devices 

The devices to be supplied ex works are equipped with hardware and software 

configurations, which meet the individual application requirements. These 

modules contain no parts that can be serviced or repaired by the user. The 

following actions will result in the exclusion of liability on the part of WAGO 

Kontakttechnik GmbH & Co. KG: 

• 

Repairs, 

• 

Changes to the hardware or software that are not described in the 

operating instructions, 

• 

Improper use of the components. 

 

Содержание 852-1102

Страница 1: ...Manual WAGO ETHERNET Accessories 852 852 1102 Industrial Switch 8 Port 1000BASE T Version 1 2 0...

Страница 2: ...45 55 E Mail support wago com Every conceivable measure has been taken to ensure the accuracy and completeness of this documentation However as errors can never be fully excluded we always appreciate...

Страница 3: ...Use Conditions for ETHERNET Devices 14 3 General 15 3 1 Package Contents 15 3 2 Industrial ETHERNET Technology 15 3 3 Switching Technology 15 3 4 Autonegotiation 15 3 5 Autocrossing 15 3 6 Functioning...

Страница 4: ...Version 1 2 0 4 6 4 Environmental Conditions 29 4 7 Approvals 30 5 Mounting 31 5 1 Installation site 31 5 2 Installation on a Carrier Rail 31 5 3 Removal from DIN Rail 31 6 Connect Devices 32 6 1 Pow...

Страница 5: ...ary 1 1 Validity of this Documentation This documentation is only applicable to WAGO ETHERNET accessory products Industrial Switch 852 1102 This documentation is only applicable from 1 2 Copyright Thi...

Страница 6: ...tes a moderate risk potentially hazardous situation which if not avoided could result in death or serious injury Personal Injury Indicates a low risk potentially hazardous situation which if not avoid...

Страница 7: ...ssories 852 Notes about this Documentation 7 852 1102 Industrial Switch Manual Version 1 2 0 Additional Information Refers to additional information which is not an integral part of this documentation...

Страница 8: ...a files are marked in italic type e g C Program Files WAGO Software Menu Menu items are marked in bold letters e g Save A greater than sign between two names means the selection of a menu item from a...

Страница 9: ...s with sufficient knowledge in automation The specialists must be familiar with the current norms and guidelines for the devices and automated environments All changes to the controller should always...

Страница 10: ...ories 852 852 1102 Industrial Switch Manual Version 1 2 0 Further details are given in the contractual agreements Please send your request for modified and new hardware or software configurations dire...

Страница 11: ...accident prevention regulations of your machine e g DGUV Regulation Electrical Installations and Equipment Emergency stop functions and equipment must not be deactivated or otherwise made ineffective...

Страница 12: ...ese switches in lockable housings cabinets or electrical operation rooms Access must be limited to authorized qualified staff having the appropriate key or tool Ensure a standard connection To minimiz...

Страница 13: ...for handling devices modules Clean only with permitted materials Clean housing and soiled contacts with propanol Do not use any contact spray Do not use any contact spray The spray may impair contact...

Страница 14: ...s behind a firewall Limit physical and electronic access to all automation components to authorized personnel only Change the default passwords before first use This will reduce the risk of unauthoriz...

Страница 15: ...scriber to send at any time because the subscriber always has an open peer to peer connection to the next switch The connection is bidirectional i e the subscriber can send and receive at the same tim...

Страница 16: ...nted with this destination address as well as the associated port 3 7 Store and forward switching mode In Store and Forward mode the ETHERNET switch caches the entire data telegram checks it for error...

Страница 17: ...17 852 1102 Industrial Switch Manual Version 1 2 0 If the connected device does not support auto negotiation or has auto negotiation disabled an auto sensing process is initiated to select the speed a...

Страница 18: ...at every port Using the industrial switch s 8 ports several segments can be set up for reducing network load and a dedicated bandwidth assigned to each user node The 852 1102 is a cost effect solutio...

Страница 19: ...ils see Section 1 PWR Status LED Power Supply Device Description Display Elements 2 RPS Status LED Redundant Voltage Supply Device Description Display Elements 3 ALM Status LED Alarm Device Descriptio...

Страница 20: ...iew of the Industrial Switch Table 4 Legend for Figure Top View of the Industrial Switch Pos Descrip tion Meaning Details see Section 1 Grounding screw 2 Terminal block male connector for power supply...

Страница 21: ...r Figure 3 Grounding screw 4 2 2 Power Supply PWR RPS The female connector Order No 2231 106 026 000 can easily be connected to the 6 pole male connector located on the top of the switch The male conn...

Страница 22: ...0 Damage to Property Caused by Electrostatic Discharge ESD Industrial switch for DC operation Power supply is provided via an external direct current power source As the industrial switch is not equip...

Страница 23: ...ails see Section 1 Connection 8 x RJ 45 10 100 1000BASE T ports Device Description 10 100 1000BASE T ports 4 2 3 1 10 100 1000Base T The 10 100 1000Base T ports support network speeds of 10 Mbit s 100...

Страница 24: ...ns 4 3 1 Device LEDs Figure 6 Device LEDs Table 7 Legend for Figure Device LEDs LED Name Status Description PWR Primary Power LED Green The primary supply voltage is connected to the industrial switch...

Страница 25: ...Network LEDs LED Name Status Description 1000 TX Port 1000 Mbit s LED 1 LED for each port Green Port in operation at 1000 Mbit s OFF Connection in operation at less than 1000 Mbit s LNK ACT LNK ACT L...

Страница 26: ...The alarm reporting function for the secondary power supply is activated OFF The alarm reporting function for the secondary power supply is deactivated 3 10 P1 P8 ON The alarm reporting function for t...

Страница 27: ...WAGO ETHERNET Accessories 852 Device Description 27 852 1102 Industrial Switch Manual Version 1 2 0 4 Turn the corresponding port DIP switch ON 5 Activate the industrial switch...

Страница 28: ...1 2 0 4 5 Label 4 5 1 Hardware and Software Version There is a label with the serial no SN on the back of the industrial switch Figure 9 Label Example Table 10 Legend for Figure Label Example No SN D...

Страница 29: ...nication Ports 8 x 10 100 1000BASE T RJ 45 Standards IEEE 802 3 10BASE T IEEE 802 3u 100BASE TX FX IEEE 802 3ab 1000BASE T IEEE 802 3x Flow Control IEEE 802 3az Energy Efficient Ethernet IEEE 802 1p C...

Страница 30: ...ersion 1 2 0 4 7 Approvals The following approvals have been granted for the WAGO ETHERNET accessory product Industrial Switch 852 1102 Conformity Marking Ordinary Locations UL61010 2 201 E175199 Tabl...

Страница 31: ...adequate Do not place any heavy objects on the industrial switch Personal Injury Caused by Hot Surface Indicates a low risk potentially hazardous situation which if not avoided may result in minor or...

Страница 32: ...ing standards for EMC compatible installations as well 2 Plug the female connector into the male connector of the switch if it has not already been plugged in Check the tight fit of the multipoint con...

Страница 33: ...ow Table 16 RJ 45 Cable Contact Description Pair Color acc EIA TIA 568B 4 wire 8 wire 1 TD D1 2 White Orange 2 TD D1 2 Orange 3 RX D2 3 White Green 4 Not assigned D3 1 Blue 5 Not assigned D3 1 White B...

Страница 34: ...of Figures Figure 1 Front View of the Industrial Switch 19 Figure 2 Top View of the Industrial Switch 20 Figure 3 Grounding screw 21 Figure 4 Power Supply PWR RPS Port 21 Figure 5 Network Connections...

Страница 35: ...end fort Figure Power Supply PWR RPS Port 21 Table 6 Legend for Figure Network Connections 23 Table 7 Legend for Figure Device LEDs 24 Table 8 Legend for Figure Network LEDs 25 Table 9 Legend fort Fig...

Страница 36: ...WAGO Kontakttechnik GmbH Co KG Postfach 2880 D 32385 Minden Hansastra e 27 D 32423 Minden Phone 49 571 887 0 Fax 49 571 887 844169 E Mail info wago com Internet www wago com...