![WAGO 852-1102 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/wago/852-1102/852-1102_manual_3158625026.webp)
26 Device Description
WAGO ETHERNET Accessories 852
852-1102 Industrial Switch
Manual
Version 1.2.0
4.4
Operating Elements
4.4.1
DIP Switches
On the top side of the industrial switch there are DIP switches to configure the
alarm and arbiter configurations.
The meaning of the DIP switch settings are described below:
Figure 8: DIP Switches
Table 9: Legend fort Figure “DIP Switches”
No. Name Status Description
1
PWR
ON The alarm reporting function for the primary power supply
is activated.
OFF The alarm reporting function for the primary power supply
is deactivated.
2
RPS
ON The alarm reporting function for the secondary power
supply is activated.
OFF The alarm reporting function for the secondary power
supply is deactivated.
3 …
10
P1 …
P8
ON The alarm reporting function for the port x connection is
activated.
OFF The alarm reporting function for the port x connection is
deactivated.
DIP switches let the user manually turn “ON/OFF” any port, the external Alarm, or
the redundant power supply.
DIP switch to the “ON” position to manually enable the alarm function for the port.
Default is “OFF”.
The following is the Recommended Procedure for configuring and setting DIP
switches during initial installation:
1.
Turn all DIP switches “OFF”.
2.
Install the industrial switch into your network.
3.
Decide which port(s) need to be monitored or should trigger the alarm.