Table 14: Technical Data – Output
Property
Value
Derating of output power
For high surrounding air temperatures, see
Line regulation
1
±1 %
Load regulation
3)
±1 %
Residual ripple/noise
< 100 mV (at 100 … 240 VAC)
Overload behavior
4)
(1.05–1.35) × IOUT: Power limitation; shutdown
in the event of a short circuit and permanent
overload
Short-circuit condition: Hiccup mode
5)
Switch-on delay
6)
110 VAC
< 1300 ms
1)
230 VAC
< 500 ms
1)
1
At nominal load
2)
At 50 % nominal load
3)
0 % / 100 % load step
4)
See “Overload Behavior” Figure
5)
See “Hiccup Mode” Figure; t
on
= 230 ms / t
off
= 2000 ms
6)
See “Switch-on Time” Figure
100%
105%
135%
140%
160%
Constant
Power Mode
24
(VDC)
0
OUT
normal
I
Overload Mode
(105 % up to 135 %)
Constant Power Mode
Short Circuit Protection
(140 % up to 160 %)
Auto Recovery
OUT
U
OUT
(ADC)
I
Figure 8: Overload Behavior