162 Configuring via the Web-Based Management System (WBM)
WAGO-I/O-SYSTEM 750
750-880, 750-880/025-000 ETHERNET Programmable Fieldbus Controller
Manual
Version 1.0.1
Figure 62: WBM page "Information"
Pos: 84.4 /Serie 750 (WAGO-I/O-SYSTEM)/Web-based Management-System/Seite Information/Information - Tabelle (750-352, -880, -881) Teil 1 @ 6\mod_1265120976715_21.doc @ 49190 @ @ 1
Table 46: WBM page "Information"
Coupler details
Entry
Default
Value (example)
Description
Order number
750-880, 750-
880/025-000/000-000
750-880, 750-
880/025-000/000-
000
Item number
Mac address
0030DEXXXXXX
0030DE000006
Hardware MAC address
Firmware
revision
kk.ff.bb (rr)
01.01.09 (00)
Firmware revision number
(kk = compatibility, ff =
functionality, bb = bugfix, rr =
revision)
Actual network settings
Entry
Default
Value (example)
Description
IP address
192.168.1.1
192.168.1.80
IP address,
Type of IP address assignment
Subnet mask
255.255.255.0
255.255.255.240
Subnet mask
Gateway 0.0.0.0
192.168.1.251 Gateway
Hostname
___
___
Host name (not assigned here)
Domainname
___
___
Domain name (not assigned here)
Pos: 84.5 /Serie 750 (WAGO-I/O-SYSTEM)/Web-based Management-System/Seite Information/Information - Tabelle (750-880, -881, -871) Zeile (S)NTP-Server @ 8\mod_1279001927768_21.doc @ 59690 @ @ 1
(S)NTP server
0.0.0.0
0.0.0.0
Address of (S)NTP server
Pos: 84.6 /Serie 750 (WAGO-I/O-SYSTEM)/Web-based Management-System/Seite Information/Information - Tabelle (750-352, -880, -881, -871, -882) Teil 2 @ 8\mod_1279001989967_21.doc @ 59694 @ @ 1