WAGO I/O SYSTEM 750 XTR
Run-time System CODESYS 2.3 243
750-8202/040-000 PFC200 2ETH RS XTR
Manual
Version 1.2.0, valid from FW Version 03.01.07(13)
8.2.3
Creating the PLC Configuration
Procedure for Creating the PLC Configuration
The procedure explained in this section describes the PLC configuration for the
I/O modules connected to the controller.
Information about the controller function for any fieldbuses connected to the
system is given in the section on the specific fieldbus.
The PLC configuration is used to configure the fieldbus controller, along with the
connected I/O modules and to declare variables for accessing the inputs and
outputs of the I/O modules.
1.
Click on the “Resources” tab.
Figure 56: “Resources” Tab
2.
In the left window double-click on “PLC configuration”. The PLC
configuration for the controller opens.