background image

Description 

 

Anwendungshinweis 

 

 

 

 

 

 

 

 

Description 

The fundamental way of carrying out the communication between the WAGO I/O 
System and the WRF06 RS-485 Modbus

®

 multifunction room operating unit from 

Thermokon is described in this application note. In addition, this application note 
describes how the visualization interface in the library can be used to configure 
the room operating unit. 

Material 

Table 3: Components 

Supplier 

Qty. 

Name 

Item No. 

WAGO 

Fieldbus Controller 

750-871 

WAGO 

4-Channel Digital Input Module, 24 VDC 

750-402 

WAGO 

4-Channel Digital Output Module, 24 VDC  750-504 

WAGO 

RS-232-/RS-485 module (configurable) 

750-652 

WAGO 

Bus end module 

750-600 

WAGO 

WAGO-I/O-

PRO

 CAA 

759-333 

Thermokon  2 

WRF06LCD DO2R 

WRF06LCD 
RS-485 
Modbus

®

 

DO2R 

 

Optional components: 

Table 4: Optional Components 

Supplier 

Qty. 

Name 

Item No. 

WAGO 

 

USB communication cable 

750-923 

 

Note 

 

Node structure 

The node structure described is only an example for the possible control of 
WRF06LCD multifunction room operating units. The modules may be 
exchanged as required by the respective application. 

Содержание 750-8 Series

Страница 1: ...Anwendungshinweis WAGO I O SYSTEM 750 ETHERNET Controller 750 8xx Connecting Multiple WRF06LCD RS 485 Multifunction Room Operating Units Modbus from Thermokon to the WAGO I O SYSTEM Version 10 04 2019...

Страница 2: ...5 55 Fax 49 0 571 8 87 84 45 55 Email support wago com Every conceivable measure has been taken to ensure the accuracy and completeness of this documentation However as errors can never be fully exclu...

Страница 3: ...1 3 Personnel Qualification 4 1 1 4 Intended Use 4 1 2 Scope of Applicability 5 1 3 Symbols 5 1 4 Number Notation 6 1 5 Font Conventions 6 2 Description 7 3 Material 7 4 Setup 8 5 Sample Program 9 5 1...

Страница 4: ...nges require the written consent of WAGO Kontakttechnik GmbH Co KG Minden Germany Non observance will entail the right of claims for damages 1 1 3 Personnel Qualification The use of the product descri...

Страница 5: ...ion New hardware and software versions may need to be handled differently Please note the detailed description in the specific manuals 1 3 Symbols Attention Attention Boundary conditions that must alw...

Страница 6: ...ams WAGO I O CHECK Menu Menu options are shown in bold e g Save A greater than between two names characterizes the selection of a menu option from a menu e g File New Input Names of input or selection...

Страница 7: ...m No WAGO 1 Fieldbus Controller 750 871 WAGO 1 4 Channel Digital Input Module 24 VDC 750 402 WAGO 1 4 Channel Digital Output Module 24 VDC 750 504 WAGO 1 RS 232 RS 485 module configurable 750 652 WAGO...

Страница 8: ...8 Table of Contents Anwendungshinweis 4 Setup Figure 1 Connection Diagram WAGO IO SYSTEM Thermokon WRF06LCD Communication Cable 750 923 Slave 2 Slave 1 A B 24 VDC A B 24 VDC...

Страница 9: ...mokon WRF06LCD multifunction room operating units WRF06LCD RS 485 Modbus The available ThermokonWRF06_01 lib library is used for this purpose 5 2 Programming The FbWRF06Master function block is used t...

Страница 10: ...of the room operating unit to be addressed is read via this function block and the input values of the unit can be changed from the controller Among other things the data read includes the current tem...

Страница 11: ...he room operating unit when there is a value change in the typWRF06_INPUT structure or when setting a bit in the bRefresh byte The tUpdateClock input can be used to set the synchronization interval If...

Страница 12: ...et point 1 and current controller mode In addition the states of the buttons on the room operating unit are also displayed The required set point 1 can be entered in the Input Set point 1 field The En...

Страница 13: ...er Note Configuration Options Depending on the WRF06 type the configuration opens may differ All settings are always displayed in the visualization However not all settings will cause a change For typ...

Страница 14: ...ion page Like all other configuration pages there is a Modbus Slave field on the top left that can be used to select the slave There is a Write button on the bottom right for writing the set configura...

Страница 15: ...messages Figure 7 Display Configuration Interface Note Text Inputs The length of the text to be input is limited to the three characters for the units and to 14 characters for the remaining texts How...

Страница 16: ...are used to configuration the buttons on the WRF06 room operating panel as well as the functions of the digital inputs Note Selection Options Non selectable settings are between the individual adjust...

Страница 17: ...Figure 9 External values Configuration Interface The External values configuration page is used to affect how the external values are displayed Units and the description of the values can be modified...

Страница 18: ...oint 2 configuration pages can be used to view and change the settings of both set points The possible settings include the display format increment adjustment limit and displayable texts In addition...

Страница 19: ...is The controller settings can be made on the Controller settings configuration page Figure 13 Fan settings Configuration Interface The last configuration page is intended for fan settings You have th...

Страница 20: ...Data Exchange with a Multifunction Room Operating Unit 11 Figure 4 Visualization Interface for Testing the Functions 12 Figure 5 Locked Configuration InterfaceBasic parameters of the selected room op...

Страница 21: ...Configuration Interface 21 Anwendungshinweis...

Страница 22: ...WAGO Kontakttechnik GmbH Co KG Postfach 2880 D 32385 Minden Hansastra e 27 D 32423 Minden Phone 49 0 5 71 8 87 0 Fax 49 0 5 71 8 87 1 69 Email info wago com Internet http www wago com...

Отзывы: