background image

 

 

 

Fieldbus Independent 
I/O Modules 

MP-Bus Master Module 
750-643 
 

 

Manual 

 

Version 1.3.0 

Содержание 750-643

Страница 1: ...Fieldbus Independent I O Modules MP Bus Master Module 750 643 Manual Version 1 3 0...

Страница 2: ...571 8 87 5 55 Fax 49 0 571 8 87 85 55 E Mail support wago com Every conceivable measure has been taken to ensure the correctness and com pleteness of this documentation However as errors can never be...

Страница 3: ...1 3 Indicating devices 12 2 1 1 4 Schematic circuit diagram 12 2 1 1 5 Technical data 13 2 1 1 6 Functional description 14 2 1 1 7 Process data 15 2 1 1 8 Data transfer 17 2 1 1 8 1 Message codes for...

Страница 4: ...ght to provide for any alterations or modifications that serve to increase the efficiency of technical progress WAGO Kontakttechnik GmbH Co KG owns all rights arising from the granting of patents or f...

Страница 5: ...loped for use in an environment that meets the IP20 protection class criteria Protection against finger injury and solid impurities up to 12 5 mm diameter is assured protection against water damage is...

Страница 6: ...Emergency stop functions and equipment shall not be made ineffective See relevant standards e g DIN EN 418 The equipment of your system shall be conform to EMC guidelines so that any electromagnetic i...

Страница 7: ...bserved to ensure smooth and efficient operation ESD Electrostatic Discharge Warning of damage to the components through electrostatic discharge Observe the precautionary measure for handling componen...

Страница 8: ...n a long term basis Warning The components are not resistant against materials having seeping and insulating properties Belonging to this group of materials is e g aerosols silicones triglycerides fou...

Страница 9: ...enu e g File New END Pushbuttons are marked as bold with small capitals e g ENTER Keys are marked bold within angle brackets e g F5 Courier The print font for program codes is Courier e g END_VAR 1 6...

Страница 10: ...s DC 24 V MP Bus supply DC 24 V MP Bus supply 0 V MP Bus supply 0 V MP Bus supply Power jumper contacts Fig 2 1 1 1 View g064300e 2 1 1 2 Description The MP Bus master module 750 643 is used for the d...

Страница 11: ...hes off the MP Bus supply Four green LEDs signal that the module is ready for use the module bus communication is free from faults and the handheld unit is enabled as well as transmit receive and the...

Страница 12: ...l TxD present off 24 V MP Bus supply not present C 24 V MP Bus supply green 24 V MP Bus supply present off Receive signal RxD not present 13 14 C D B A D C B A Fig 2 1 1 2 Indicating devices g063802x...

Страница 13: ...ehavior Automatic restart on return of power Supply voltage internal via system voltage DC DC Current consumption internal 15 mA Potential isolation 500 V System MP Bus Data width internal 1 byte C S...

Страница 14: ...h a programmable fieldbus controller When a programmable fieldbus controller is used several IEC 61131 3 function blocks are required for the MP Bus master functions The task of the function blocks is...

Страница 15: ...e stored in 6 output bytes D0 D5 and 6 input bytes D0 D5 Two control bytes C0 C1 and two status bytes S0 S1 are used to control the data flow The bytes C1 and S1 are transferred as data bytes but are...

Страница 16: ...Process data exchange 1 Register communication 0 Reserved Extended control byte C1 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 MC3 MC2 MC1 MC0 0 0 DA DR DR Data Request toggle mode New output dat...

Страница 17: ...in the status byte for the direction to the fieldbus controller In order to safeguard the sequence of data packets a transaction number TNO is assigned for each set of associated partial data packets...

Страница 18: ...message code K2F_COM_T0 as a reply 0 D0 4 MP Bus telegram according to specification without length and cross parity 0 D5 TNO 1 D0 4 MP Bus telegram according to specification without length and cross...

Страница 19: ...0 D5 TNO 1 D0 D3 Data received 1 D4 not used 1 D5 TNO ERR 1 0 D0 Error number 0 D1 Extended error status 0 D2 D4 not used 0 D5 TNO 1 D0 D4 not used K2F_TEST 2 1 D4 TNO ERR 0 Transmission confirmation...

Страница 20: ...Error number 0 D1 Extended error status 0 D2 Function macro ID 0 D3 D4 not used 0 D5 TNO 1 D0 D4 not used K2F_FM 6 1 D5 TNO 2 1 1 8 3 Use of the module 750 643 with programmable fieldbus controllers...

Страница 21: ...s lib Version 1 6 or later No function can be guaranteed if the versions do not match 2 1 1 8 3 2Overview of function blocks Further device specific function blocks are available as well as the master...

Страница 22: ...a response and thus relieve the burden on the module bus and the function blocks Appropriate function macros are available for Type 1 and Type 2 MP Bus addressing These macros are used by the function...

Страница 23: ...after requesting the serial number 0 D2 4 Serial number of the programmed MP Bus device 0 D5 TNO 1 D0 3 Serial number of the programmed MP Bus device 1 D4 not used K2F_FM 1 1 D5 TNO MP Bus addressing...

Страница 24: ...re be made up using commercially available installation cable Note To simplify the wiring special ribbon cables with adapters for connecting MFT drives and sensors to the MP Bus are obtainable from Wo...

Страница 25: ...YSTEM 750 I O Modules Fig 2 1 1 4 MP Bus length as a function of the active power of all drives p064305x Example Total active power of all drives Wtot 10 W Diagram curve Core cross section Bus length...

Страница 26: ...ti Function Technology Damper drives MFT 2 valve drives MFT fire prevention damper drives and VAV compact controllers as well as the Belimo FLS window ventilation system are available Further informat...

Страница 27: ...lave MP Master Sensor Slave Slave Sensor Slave Sensor Fig 2 1 1 6 MP Bus topologies g064306x One sensor can be connected per drive Drive Connectable sensor MFT Active sensor Output DC 0 32 V Switch ON...

Страница 28: ...associated status bit in the extended status byte via the module bus The module also switches off its master functionality when the 24 V supply voltage is applied to the Enable Handheld input The sys...

Страница 29: ...750 643 MP Bus Master Module 29 Network structure WAGO I O SYSTEM 750 I O Modules...

Страница 30: ...WAGO Kontakttechnik GmbH Co KG Postfach 2880 D 32385 Minden Hansastra e 27 D 32423 Minden Phone 05 71 8 87 0 Fax 05 71 8 87 1 69 E Mail info wago com Internet http www wago com...

Отзывы: