2789-9023
Commissioning
Product manual | Version: 1.0.0
49
EtherNet/IP Communication Module
7.1.2 Setting a Static IP Address
To use the IP address permanently, you can switch the addressing to “static.” The follow-
ing options are available for this:
• Setting the IP address via the WBM
• Setting the default IP address with the reset button
• Setting the IP address via the Modbus command
Setting the IP Address via the WBM
1. Open the WBM (Web-Based Management) of the communication module in a
browser.
2. Switch to the
Module Settings > Network
page of the WBM.
3. In the
Ethernet Settings
area, you can make the required network settings.
Figure 9: Module Settings > Network
Note
The communication module must be restarted for the settings to be applied.
4. To restart, press the
[Start]
button in the
Reboot
section of the
Module Settings >
System
page of the WBM, or power cycle your system.