2787-2154
Configuration
Product manual | Version: 1.0.2
47
Power Supply Pro 2
System
Figure 28: Dialog: Settings – System
Table 54: Dialog: Settings – System
Section
Parameters
Description
General
Restore previous status
1)
If this checkbox is selected, the previous state of the
product is restored in the event of connection to the
grid.
DC output to be switched on
1)
If this checkbox is selected, the DC output is switched
on in the event of connection to the grid.
DC output remains switched
off
1)
If this checkbox is selected, the DC output remains
switched off in the event of connection to the grid.
Switch-on delay active
If this checkbox is selected, an additional switch-on de-
lay is enabled in the event of connection to the grid.
Switch-on delay
Here you can enter the switch-on delay (unit: ms).
Disable reset to factory set-
tings
If this checkbox is selected, it is not longer possible to
reset the product to the factory settings using the but-
tons.
Activate key lock
If this checkbox is selected, a button lock feature is ac-
tivated. No functions can be performed with the but-
tons. However, it is still possible to reset the product to
the factory settings.