Operating manual Piston pump IceBreaker 40-200 ccm (Finishing)
7 Operation
50
Order number 2333538 | Edition 03/2021
NOTICE
Hardened working product in the spraying system when 2K product is processed!
Using 2K materials can destroy the pump and spraying system.
4
Observe the manufacturer's processing rules, particularly in regards to the pot life.
4
Flush thoroughly before the end of the pot life.
4
The pot life is decreased by warmth.
7.5 BASIC FLUSHING
Regular flushing
– Regular flushing, cleaning and maintenance ensures the pump's high conveying and
suction capacity.
– The cleaning and flushing agents used must be compatible with the working material.
– Do not flush hardener pumps with water. Only flush them using suitable flushing agents
(solvents).
WARNING
Incompatibility of cleaning/flushing agent and working medium!
Risk of explosion and danger of poisoning by toxic gases.
4
Examine the compatibility of the flushing and cleaning agents and working media
on the basis of the safety data sheets.
6
7
4
1
3
B_05292
5
2
A
B
A
Closed
B
Open
Before each basic flushing, the nozzle must be removed from the spray gun. Here, the
specifications in the spray gun operating manual must be followed. With AirSpray systems,
carry out the basic flushing of the system without atomizing air.