102
VERSION 10/2018
ORDER NUMBER DOC 2339321
.
9.2.10 CLEANING OR REPLACING THE PRODUCT FILTER
9.2.10.1 ANGLED INLINE FILTER (530 BAR)
1. Flush the pump and inline filter in accordance with Chapter
with pump's operating manual.
Flush using the gun so that the flushing agent flows through the inline filter. Maximize the flow
(remove the nozzle, open the dosing valve if necessary).
2. Empty the pump in a controlled manner in accordance with Chapter
and the pump's operating
manual.
3. Place the grounded collection tank under the inline
filter.
Flow dir
ection
* For order no., see spare parts catalog.
53 MPa
530 bar
7687 psi
B_07113
C*
B
D
E
A*
E
F*
4. Unscrew the filter by turning the handle (D).
5. Remove the filter insert (C).
6. If the inline filter has any leaks: Replace the seal (A).
7. Insert the new filter insert (C). Note the installation
position: closed end in direction of flow.
8. If necessary, coat the thread with anti-seize paste (F).
9. Assemble the turning handle (D), inlet housing (B)
and outlet housing (E) and tighten by turning the
handle.
10. Clean the spray gun's product filter in accordance
with the spray gun's operating manual.
11. Fill pump in accordance with Chapter
and the
pump's operating manual.
9.2.10.2 STRAIGHT INLINE FILTER (270 BAR)
1. Flush the pump and inline filter in accordance with Chapter
and with pump's operating manual.
Flush using the gun so that the flushing agent flows through the inline filter. Maximize the flow
(remove the nozzle, open the dosing valve if necessary).
2. Empty the pump in a controlled manner in accordance with Chapter
and the pump's operating
manual.
3. Place the grounded collection tank under the inline filter.
27 MPa
270 bar
3916 psi
* For order no., see spare parts catalog.
Flow dir
ection
B_05274
2
3
5
1
**
4. Unscrew the inlet housing (B) and outlet housing (E) with two
size 19 wrenches.
5. Remove the filter insert (C).
6. If the inline filter has any leaks: Replace the seal (A).
7. Insert the new filter insert (C). Note the installation position:
closed end in direction of flow.
8. If necessary, coat the thread with anti-seize paste (F).
9. Screw together the inlet housing (B) and outlet housing (E)
with two size 19 wrenches.
10. Clean the spray gun's product filter in accordance with the
spray gun's operating manual.
11. Fill pump in accordance with Chapter
and the pump's
operating manual.