38
VERSION 01/2018
ORDER NUMBER DOC 2385674
TOPFINISH Bell 1S
6.7.2 VENTILATION OF THE SPRAY BOOTH
The electrostatic spraying equipment may only be operated in defined spraying areas and
in accordance with the EN 12215 standard or under comparable ventilation conditions.
The electrostatic spraying equipment must be locked to the technical ventilation
so that the coating product supply and the high voltage are not effective as long as
the technical ventilation is not operated with the minimum exhaust air volume flow
or a larger exhaust air volume flow.
Operate the device in a spray booth approved for the working materials.
Observe national and local regulations for the exhaust air speed.
Ensure that the excess coating product (overspray) will be collected up safely.
6.7.3 AIR SUPPLY LINES
Ensure that only dry, clean atomizing air penetrates the high-speed rotary atomizer! Dirt
and moisture in the atomizing air worsens the spraying quality and spray pattern.
WARNING
Hose connections!
Risk of injury and damage to the device.
Do not mix up hose connections of product hose and air hose.
6.7.4 PRODUCT SUPPLY LINES
NOTICE
Impurities in the spraying system!
High-speed rotary atomizer blockage, product hardens in the spraying system.
Flush high-speed rotary atomizer and paint supply with suitable flushing agent.
6.8
GROUNDING
WARNING
Discharge of electrostatically charged components in atmospheres containing
solvents!
Explosion hazard from electrostatic sparks.
Clean the pump only with a damp cloth.
WARNING
Heavy paint mist if grounding is insufficient!
Danger of poisoning.
Insufficient paint application quality.
Ground all device components.
Ground the work pieces to be coated.