Calibrated  for 

 Douglas fir 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 

INSTRUCTIONS 

And Species Adjustment Tables 

 

Model L601-3 Hand-Held Moisture Meter 

 

1-800-634-9961 

 

Содержание L601-3

Страница 1: ...Reference Calibrated for Douglas fir INSTRUCTIONS And Species Adjustment Tables Model L601 3 Hand Held Moisture Meter 1 800 634 9961...

Страница 2: ...CTIONS 4 TAKING MEASUREMENTS 5 METER CALIBRATION 5 METER STORAGE 5 QUESTIONS ANSWERS 6 SPECIES ADJUSTMENT TABLE 11 SPECIFIC GRAVITY VS MOISTURE CONTENT 14 OTHER MATERIALS 15 ZERO ADJUSTING 16 WARRANTY...

Страница 3: ...ness cross section method used when performing the ASTM D 4442 92 oven dry lab method This ASTM standard and its international counterparts is the standard to which all moisture meters for wood are co...

Страница 4: ...ur species and the corresponding meter reading Example Your meter reading is 13 Figure1 Your species is Basswood American Locate your species in the tables provided Find the species in the appropriate...

Страница 5: ...covered by the wood you are measuring If the sensing area is not completely covered your moisture reading will be inaccurate Additional meter corrections may be necessary if you are measuring Raft Wo...

Страница 6: ...y companies use their hand held meters from Wagner Meters to read right through the plastic wrapping around the wood on new deliveries before they allow unloading 3 Where Readings are Taken Q Where is...

Страница 7: ...n measure accurately with this hand held meter from Wagner Meters A Model L601 3 measures boards as narrow as 2 in width 6 Board Thickness Q What board thickness can I measure A Model L601 3 meters ar...

Страница 8: ...ngth and breadth However using a hand held moisture meter from Wagner Meters you can quickly and easily scan 4x lumber on both sides 4 x 4 s on all four sides Then only the center 1 5 8 would be unmea...

Страница 9: ...it does Note It s important on rough material to use some pressure and hold the meter down firmly against the wood Occasionally the measurement of exceptionally rough material may necessitate adding 1...

Страница 10: ...e wood is to be used in construction as a stud for building the moisture content requirement could be 15 to 19 If the wood is to be glued and it is too dry it will not bond if it is too wet it will no...

Страница 11: ...5 16 5 17 5 18 5 19 5 20 5 21 5 22 5 24 0 25 0 26 0 27 0 28 0 29 0 30 0 31 0 32 0 33 0 34 5 35 5 0 47 Cedar Eastern red cedar 6 0 7 0 8 0 9 0 10 0 11 0 12 0 13 0 14 0 15 0 16 0 16 5 17 5 18 5 19 5 20...

Страница 12: ...2 5 23 5 24 5 0 50 Magnolia Southern 5 5 6 5 7 5 8 5 9 5 10 5 11 5 12 0 13 0 14 0 15 0 16 0 17 0 18 0 19 0 19 5 20 5 21 5 22 5 23 5 24 5 25 5 26 5 27 0 28 0 29 0 0 44 Mahogany African 7 0 8 0 8 5 9 5...

Страница 13: ...0 0 35 Pine Western white 8 5 9 5 10 5 11 5 12 5 13 5 14 5 15 5 16 5 18 0 19 0 20 0 21 0 22 0 23 0 24 0 25 0 26 0 27 0 28 0 29 0 30 0 31 0 32 0 33 5 34 5 0 42 Primavera 7 0 8 0 9 0 10 0 11 0 12 0 13...

Страница 14: ...5 11 5 12 0 13 0 14 0 15 0 16 0 17 0 18 0 19 0 19 5 20 5 21 5 22 5 23 5 24 5 25 5 26 5 27 0 28 0 29 0 0 51 5 5 6 5 7 5 8 0 9 0 10 0 11 0 12 0 13 0 14 0 15 0 15 5 16 5 17 5 18 5 19 5 20 5 21 5 22 0 23...

Страница 15: ...nt area contains more moisture than another i e measurements that do not require a high absolute accuracy SG formulas can t be applied to non solid wood species due to the presence of glues and resins...

Страница 16: ...igure 1 until the needle rests precisely on the lowest mark on the scale Figure 2 2 Remove the DRY BOX ZERO cap Figure 1 Hold the meter in midair so that the bottom is level and several feet from any...

Страница 17: ...ime Wagner Meters recommends purchasing a calibration verification block or returning the unit to the factory for diagnostic checkup and recalibration on the anniversary date of purchase each year the...

Страница 18: ...18 NOTES...

Страница 19: ...grantee or manufacturer could void the user s authority to operate such equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device...