
25
GM 4700AC
OPERATING MANUAL
VERSION 06/2014
ORDER NUMBER DOC2311730
6.5
GROUNDING
A conductive connection (potential equalization cable) must be established between
original bundles and the equipment.
WARNING
Heavy paint mist if grounding is insuffi
cient!
Risk of poisoning.
Insuffi
cient paint application quality
Ground all device components.
Ground the work pieces to be coated.
WARNING
Discharge of electrostatically charged components in
atmospheres containing solvents!
Explosion hazard from electrostatic sparks or fl ames
Ground all device components.
Ground the work pieces to be coated.
Carry out safety checks in accordance with Chapter 8.2.3.
6.6
SAFETY CHECKS
The viscosity of the lacquer is of great importance. The best spraying results are obtained
with values between 80 and 260 milli Pascal x Sec (mPas).
Please also read the technical data sheet of the lacquer for optimal processing, viscosity
adjustment and intermixing of the product.
6.7
PREPARATION OF LACQUER
Содержание GM 4700AC
Страница 2: ......
Страница 55: ...55 GM 4700AC 55 GM 4700AC OPERATING MANUAL VERSION 06 2014 ORDER NUMBER DOC2311730...
Страница 79: ......