Operating manual GA 5000EAC Electrostatic Automatic Spray Gun (AirCoat)
7 Operation
Order number 2360922 | Edition 09/2022
41
Flat-jet method: Changing the spray jet width
B_05776
1
1. Change the spray jet width by selecting the appropriate nozzle.
2. By turning the air regulation (1), the spray jet can additionally be adjusted (IC variant).
3. Increase or decrease shaping air (EC variant).
Round-jet method
B_05777
2
3
4
By gently turning the nozzle nut (2), the atomizing air jet can additionally be adjusted.
ð
Do not completely tighten the nozzle nut
:
Do not turn the nozzle nut (2) until it is flush with the nozzle body (3). There must be
play for the atomizing air between the nozzle nut and the nozzle body.
Flow rate
The flow rate can be reduced by:
1. Minimizing the product pressure.
2. Using a different nozzle size (see chapter Accessories [
69]).
7.5 PRESSURE RELIEF / WORK INTERRUPTION
The pressure must always be relieved:
– after the spraying tasks are finished,
– before servicing or repairing the spraying system,
– before carrying out cleaning tasks on the spraying system,
– before moving the spraying system to another location,
– before something must be checked on the spraying system,
– Before the valve seat is replaced on the spray gun.
Observe general safety instructions in chapter Basic Safety Instructions [