3
IDENTIFICATION
3.1
EXPLOSION PROTECTION IDENTIFICATION
As defined in the Directive 2014/34/EU (ATEX), the device is suitable for use in potentially
explosive areas.
Device type:
AirCoat automatic gun
Manufacturer:
Wagner International AG
9450 Altstätten
Switzerland
II 2G X
CE
European Communities
Ex
Symbol for explosion protection
II
Device class II
2
Category 2 (zone 1)
G
Ex-atmosphere gas
X
Special notice
3.2
IDENTIFICATION "X"
The maximum surface temperature corresponds to the permissible product temperature.
This and the permissible ambient temperature can be found in the "Technical Data"
chapter.
Safe Handling of WAGNER Spray Devices
Mechanical sparks can form if the device comes into contact with metal.
In an explosive atmosphere:
Do not knock or push the device against steel or rusty iron.
Do not drop the spray gun.
Use only tools that are made of a permitted material.
Ignition temperature of the coating product
Ensure that the ignition temperature of the coating product is above the maximum
surface temperature.
Medium supporting atomizing
To atomize the product, use only weakly oxidizing gases, e.g., air.
Cleaning
If there are deposits on the surfaces, the device may form electrostatic charges. Flames or
sparks can form during discharge.
Remove deposits from the surfaces to maintain conductivity.