6.6.1 Grounding the powder coating system
P_01120
1
2
3
6
7
5
4
1
Only use mains cables with grounding strand!
2
Connect grounding cable with booth or spray wall and signal ground!
3
Connect grounding cable to an uncoated metal part of the booth or spray wall!
4
Remove all paint from hooks and other hanger parts!
5
Do not wear insulating gloves!
6
Wear electrostatically conductive footwear!
7
The floor must be electrostatically conductive!
6.6.2 Safety Checks
A skilled person must check to ensure that the device is in a reliable state after it is
assembled and commissioned. This includes:
4
Carry out safety checks in accordance with Chapter Safety Checks [
52].