22
VERSION 01/2018
ORDER NUMBER DOC 2340851
Cobra 40-10 / 40-25
5.5.4 VOLUME FLOW
Wagner AL nozzles
Volume flow in l/min.*
inch
mm Spray angle
at
at
at
7 MPa
10 MPa
15 MPa
70 bar
100 bar
150 bar
1015 psi
1450 psi
2175 psi
0.007
0.18
40°
0.1650
0.2000
0.2400
0.009
0.23
20-30-40-50-60°
0.2060
0.2500
0.3090
0.011
0.28
10-20-30-40-50-60°
0.2950
0.3450
0.4260
0.013
0.33
10-20-30-40-50-60-80°
0.4530
0.5280
0.6600
0.015
0.38
10-20-30-40-50-60-80°
0.5770
0.6720
0.8130
0.017
0.43
20-30-40-50-60-70°
0.7310
0.7860
1.0640
0.019
0.48
20-30-40-50-60-70-80°
0.9260
1.0920
1.3700
0.021
0.53
20-40-50-60-80°
1.1430
1.3600
1.6900
0.023
0.58
20-40-50-60-70-80°
1.3700
1.5900
2.0100
Cobra 40-10
0.025
0.64
20-40-50-60-80°
1.6200
1.9100
2.4000
0.027
0.69
20-40-50-60-80°
1.8300
2.1300
2.6800
0.029
0.75
60°
2.1900
2.5100
3.1700
0.031
0.79
20-40-50-60°
2.4000
2.7700
3.4900
0.035
0.90
20-40-50-60°
3.2200
3.7400
4.6900
Cobra 40-25
0.043
1.10
20-50°
5.0700
6.0400
7.4600
0.052
1.30
50°
5.1200
6.5000
7.5200
Volume flow refers to water.
−