5000 Watt AC Inverter by Wagan Tech

3

User’s Manual—Read before using this equipment 

4

FRONT PANEL 

The Front Panel view shows the inverter’s ON/OFF Switch, Indicators, direct wiring High 

Current Terminals, four AC Outlets and optional Remote Switch Connector.

ON/OFF Switch

This switch controls operation of the inverter.

Over Temp LED

This indicator turns RED as the inverter shuts down because of excessive temperature. 

Immediately turn off appliances if this occurs. Allow the inverter to cool before continuing. 

Internal high-speed cooling fans automatically turn on when the inverter is switched on to 

provide instant cooling. The inverter may overheat when it is being used in a location that 

does not allow for adequate ventilation.

ON/OFF 

Switch

Over Temp 

LED

Overload 

LED

High Output 

Terminals

Bar Graph 

Displays

Four 115V 

AC Outlets

Remote 

ON/OFF 

Switch 

Connection

Overload LED 

This indicator turns RED as the inverter shuts down. Immediately turn off some appliances 

to reduce the load. If the continuous combined power requirement of appliances being 

operated exceeds 5,000 watts, the inverter will overload. Sometime an appliance with very 

high startup load will cause the inverter to shut down. If battery condition and cables should 

support the load, then a higher wattage inverter is required. 

Bar Graph Displays

The inverter is equipped with two bar graph displays to monitor DC input to the inverter. 

These are used to help diagnose problems if they occur.

Volts Bar Graph: 

This display is the measurement of the voltage at the DC terminals of the inverter, not 

actual battery voltage. During high wattage applications the display may show a lower 

voltage level than the battery because of voltage drop that occurs between the DC 

input cables and the battery. This voltage drop should not be greater than 0.25 volts, 

as a greater voltage will seriously reduce run time. This inverter will operate with input 

voltage ranging from 10.5 to 15 volts of direct current (DC). If the inverter input voltage 

level falls below 10.5 volts DC, an audible alarm will sound. When the voltage drops 

below 10 volts DC, the inverter will automatically shut down. 

During charging from a generator, solar panel or AC powered charger the battery 

voltage will be higher than when it is resting. This inverter will automatically shutdown 

if the input voltage is 15 volts or higher. Voltages that are greater than 15 may cause 

damage to the inverter. Damage caused by excessive voltage input is not covered 

under warranty. 

Amps Bar Graph: 

This display indicates actual DC amperes of current being drawn from the battery 

bank. Note that the AMPS display indicates a range of 120 to 600 amps. Current less 

than 120 amps is not displayed. Note that for a 120 Amp reading the inverter should 

be powering 1,200 watts of AC load.  

High Output AC Terminals 

There are three insulated terminals on the front panel of the inverter. These terminals are for 

connecting 115 volt AC devices that require more than 15 amps to operate. Other uses are 

for connection to distributed wiring that has multiple AC outlets. Any wiring that is directly 

connected must be 10 gage or larger. Facing the front panel, the terminals are:

Left

Middle

Right

Ground

Neutral

Hot

www.wagan.com

© 2010 Wagan Corporation

All Rights Reserved

Wagan and wagan.com are trademarks used by Wagan Corporation

Содержание AC Inverter

Страница 1: ...Item no 2012 User s Manual 5000 Watt AC Inverter R ...

Страница 2: ...ide LOAD CONSIDERATIONS When an appliance with a motor starts it requires an momentary surge of power This surge of power is the starting load or peak load Once started the appliance requires less power to continue to operate This is known as the continuous load It is important to know the starting loads and the continuous loads of the appliances that are to be powered by the inverter Appliance po...

Страница 3: ...ltage at the DC terminals of the inverter not actual battery voltage During high wattage applications the display may show a lower voltage level than the battery because of voltage drop that occurs between the DC input cables and the battery This voltage drop should not be greater than 0 25 volts as a greater voltage will seriously reduce run time This inverter will operate with input voltage rang...

Страница 4: ...nary AC voltmeters are calibrated to read average voltage and assume that the AC waveform will be a pure sine wave These meters will not correctly read MSW voltage and will display about 20 to 30 volts too low Any multi meter identified as TRUE RMS will accurately read MSW correctly INVERTER OUTPUT CHARACTERISTICS The high output terminals and outlets of this inverter are wired in a similar manner...

Страница 5: ...watts this can cause immediate overload shut down At 5 000 watts continuous output this inverter requires a DC power supply battery bank that can continuously supply 500 amps at 12V DC for the duration of the run time CONFIGURING THE BATTERY BANK To determine the minimum battery ampere hour rating that you will need to operate appliances from the inverter and any DC appliances powered by the batte...

Страница 6: ...id battery under load providing that it has an AH rating at the 20 hour rate Continuing with the previous example the 150 amp load will need to run for 10 hours so we begin configuration with a 1 500 AH battery If the vertical is 1 500 and the horizontal is 150 amps the percentage of load on the battery is 10 The curve shows that the 1 500 AH is derated to 90 of maximum This means that the battery...

Страница 7: ... front panel of the inverter is in the OFF 0 position Disconnect any remote switch from the connector on the front panel 4 Locate the ground lug terminal at the rear of the inverter Connect an insulated 6 gage copper wire to the terminal The other end of the ground wire is connected to a proper grounding point Use the shortest practical length of wire Connect this wire to the chassis of your vehic...

Страница 8: ... has 16 500 AH of capacity as in the example above and has been discharged to 10 5 volts discharged The charger has to replace 2145 AH 1650 x 1 3 AH in 14 hours So the charger must charge at a rate of 153 amps for 14 hours As this charge current is distributed among the batteries in the battery bank the current received by an individual battery is within its charge rating Be sure that the battery ...

Страница 9: ...or weak battery condition Recharge or replace battery Inadequate power being delivered to the inverter or excessive voltage drop Use lower gauge wire Keep wire length as short as possible PROBLEM TV does not work Reason Solution TV does not turn on Contact TV manufacture to see if the TV is compatible with a modified sine wave SPECIFICATIONS Name Description Input 12V 10 15V DC Output 115V AC Outp...

Страница 10: ...on will at its option replace or repair the defective part A Returned Merchandise Authorization number RMA is REQUIRED when sending in any defective item WAGAN Corporation is not responsible for any item s returned without an official Returned Merchandise Authorization number The item s must be returned with prepaid shipping WAGAN Corporation is not responsible for any shipping charges incurred in...

Страница 11: ...agan com U S A CAN Toll Free 1 800 231 5806 1 510 471 9221 31088 San Clemente Street Hayward CA 94544 U S A 2008 2010 Wagan Corporation All Rights Reserved Wagan and wagan com are trademarks used by Wagan Corporation Revised May 2010 ...

Отзывы: