35
Installation
CoolAir
➤
Use the
+
and
–
buttons (fig.
7
on page 5, item 6 and 7) to set the val-
ue for low voltage shutdown. The characteristic figures at second and
third place on the digital display represent the voltage (V) at which the
unit is shut down:
➤
Press the
Operating Mode
button (fig.
7
on page 5, item 4) to con-
firm your entry.
✓
The set value is saved and is then used when the unit is restarted.
✓
You are now in menu level 2 again and can use the
+
and
–
buttons to
switch between menu levels.
6.3.4
Menu level 3: Operating mode
The unit always starts with a defined operating mode for room tempera-
ture. This parameter can be configured:
➤
Start configuration mode (see Chapter "Starting and ending configu-
ration mode" on page 33).
✓
The first digit of the display (fig.
7
on page 5, item 5) shows the menu
level and the second and third show the parameter which can be set.
➤
Press the
+
button (fig.
7
on page 5, item 6) twice to switch to menu
level
3
.
➤
Press the
Operating Mode
button (fig.
7
on page 5, item 4) to
change the parameters.
✓
The digits in the display flash until the parameter you entered is con-
firmed.
➤
Use the
+
and
–
buttons (fig.
7
on page 5, item 6 and 7) to set the
mode with which the unit starts up:
Characteristic
figure
Low voltage
shutdown
Characteristic
figure
Low voltage
shutdown
1
22,2
6
23,0
2
22,4
7
23,1
3
22,6
8
23,2
4
22,8
9
23,4
5
22,9
10
23,6
Characteristic fig-
ure
Operating mode
0
Automatic mode
1
Operating mode 1
2
Operating mode 2
3
Operating mode 3
CA-850S_EBA.book Seite 35 Mittwoch, 8. September 2010 7:31 19
Содержание Coolair CA850S
Страница 3: ...3 CoolAir 179 276 353 1 830 2 1 3 CA 850S_EBA book Seite 3 Mittwoch 8 September 2010 7 31 19...
Страница 4: ...CoolAir 4 4 1 2 3 4 7 6 5 5 CA 850S_EBA book Seite 4 Mittwoch 8 September 2010 7 31 19...
Страница 5: ...5 CoolAir 6 1 6 2 3 4 5 8 7 7 CA 850S_EBA book Seite 5 Mittwoch 8 September 2010 7 31 19...