Service tasks
VAS 6380B / VAS 6381B
46
3. Use the cursor keys
or
to select
“Service.”
:
4. Press
ENTER
to confirm.
5. Enter the password “
2224
”.
6. Confirm
“Pressure transducer”
with
“ENTER”
.
7. Then follow the instructions in the display.
– Unscrew the service couplings (
12
) and (
13
) from the service
hoses (
10
) and (
11
).
– Use the keypad (
7
) to enter the current local atmospheric pressure
and press
ENTER
to confirm.
I
8. When calibration has been completed, press
ENTER
to quit the
menu.
9. Press
STOP
twice to go to standby menu.
10. Screw the service couplings (
12
) and (
13
) hand-tight onto the
service hoses (
10
) and (
11
) again, taking care not to mix up the red
and blue markings on the couplings and hoses.
9.6
Changing the vacuum pump oil
!
1. Before changing the oil, let the vacuum pump run for about
10 minutes (manually using the menu).
I n t . v e s s e l f i l l i n g
F l u s h i n g
R e s e t S c a l e s .
S e r v i c e .
NOTE
You can look up the current atmospheric pressure for your region on the
Internet, for example at http://www.meteo24.de/wetter/ under “air
pressure”.
WARNING! Danger of fatal electric shock
Touching uninsulated parts may result in serious injury.
Switch off the AirCon Service Center and unplug it from the power
supply before opening the housing.
The AirCon Service Center may only be repaired by personnel
authorized by Dometic.
WaecoVAS6380B-6381B_OPM_4445101232_AMER(us)_202x-xx-xx.book Seite 46 Montag, 2. November 2020 4:18 16