Operation
VAS 6380B / VAS 6381B
36
4. Confirm both settings with
ENTER
.
I
8.8.3
Filling process
1. Select desired settings and press
ENTER
to confirm.
2. If “
Filling phase?
” has been selected, enter the desired values,
otherwise continue with chapter “Selecting connections” on page 37.
3. Enter the amount of refrigerant.
4. Press the cursor key
.
5. Enter the amount of additive.
6. Press the cursor key
.
7. Enter the amount of refrigerant.
8. Confirm all settings with
ENTER
.
I
V a c u u m t i m e m i n .
L e a k T e s t m i n .
E N T E R - O K S T O P - E X I T
NOTE
The air conditioning system is deeply drained by the vacuum pump.
This is used to remove any foreign gases or moisture and to prepare the
air conditioning system for the filling process.
F i l l i n g p h a s e ?
E N T E R - O K S T O P - E X I T
P A G O i l m l .
U V T r a c e r m l .
R e f r i g e r a n t g .
E N T E R - O K S T O P - E X I T
NOTE
If an extraction process takes place in the same process, the
quantity of fresh oil counts as an extra filling quantity, which is added
to the previously extracted quantity of used oil. If you set this value
to 0, the exact amount of oil that has been extracted is also refilled.
To add fresh oil or UV additive, a vacuum process must be per-
formed in the same process sequence. If no vacuum process has
been selected, only refrigerant can be selected in the filling menu.