background image

Goldseal Plus

Operators manual

 

Fault Finding

No Mains light Or Control Display

Check the supply to press and condition of fuses (front panel & plug)
Is the press switched on?
Control Unit Transformer output of 12vac ?

Heat plate fails to get warm (refer to fig.2)

Does the element have continuity? 

*

Does the probe have resistance? 
Is the relay switching over?  (check SSR, and coil supply)

RTD Probe.

To test the probe condition  remove completely from press and measure
 the resistance at room temperature using a multimeter.
Then warm the probe if the resistance changes the probe is working correctly. 
This will only give you an approximation of the condition of the part.

Sealing Pressure Low.

Severely worn pad
Over compressed springs
Toggle links worn

Timer Buzzer 

Toggle arm not making contact with micro-switch
Faulty micro-switch, check switching with meter.
Buzzer faulty check AC power supply to buzzer 230VAC.

Safety First

  

When working on the heat press remember to always 

DISCONNECT

 the mains supply

before removing covers or guards. Never allow your hands to be in a position that they may be trapped

by the heat plate when you bring the handle down.

4

Controller Error Codes

Out of range signals

The upper display shows the OVER-RANGE and UNDER-RANGE conditions with
the following indications:
Over-range

 Under-range

The sensor break will be signalled as an out of range

NOTE: 

When an over-range or an under-range is detected, the alarms operate as

in presence of the maximum or the minimum measurable value respectively.
To check the out of span Error condition, proceed as follows:
1) Check the input signal source and the connecting line.
2) Make sure that the input signal is in accordance with
the instrument configuration.
Otherwise, modify the input configuration 
3) If no error is detected, send the instrument to your supplier to be checked

.

ErAT - Fast Auto-tune can’t start. The measure value is too close to the set point.
Push the P button in order to delete the error message.
NoAt - Auto-tune not finished within 12 hours.
ErEP- Possible problem of the instrument memory.
The messages desappears automatically.
When the error continues, send the instrument to your supplier

Содержание Goldseal Plus

Страница 1: ...Operators Manual Rev GSW Plus 2020 K32 ...

Страница 2: ... platen and gradually heat up to the set point The controller on the left is indicating 210 C this means the machine is ready to use 204 C post 2019 machines The second display green line is the timer set point in seconds currently set to 8 seconds The machine is delivered set to standard factory settings as above but you may wish to change these for different materials or marking products You may...

Страница 3: ... free from defects in materials and workmanship for a period of 12 months from the proven date of delivery or installation Should in our opinion any part of this press be defective in materials or workmanship it will be replaced or repaired free of charge excluding any travelling costs carriage costs which will be charged at our discretion provided that the press has been installed and operated in...

Страница 4: ...mains supply before removing covers or guards Never allow your hands to be in a position that they may be trapped by the heat plate when you bring the handle down 4 Controller Error Codes Out of range signals The upper display shows the OVER RANGE and UNDER RANGE conditions with the following indications Over range Under range The sensor break will be signalled as an out of range NOTE When an over...

Страница 5: ...ILICONE PRESSURE PAD GSW 17 PRESSURE PAD PLATE grade 525 GSW 18 PTFE pack of 5 GSW 19 MAIN TOGGLE SPRING Arm return spring GSW 22 RTD PROBE GSW 23 PROBE RETAINER GSW 24 MICRO SWITCH Timer actuation GSW 26 BASE BOARD GSW 27 RUBBER FEET GSW 28 MAINS LEAD PL 08 MAINS INLET FlANGE FIXING 10amp GSW 32 PACKAGING GSW 33 plus INSTRUCTION BOOK GSW 34 SET OF SCREWS Complete GSW 36 MICRO SWITCH GASKET GSW 37...

Страница 6: ...Goldseal Plus Operators manual 6 ...

Страница 7: ...Goldseal Plus Operators manual 7 ...

Отзывы: