2.8

Troubleshooting

Problem

Reason

Remedy

Balloon does not open.

The stop bolt is not pulled 
out before attempting to 
push the black hand grip 
downward.

Pull out the stop bolt and 
attempt to push down 
again.

If the balloon still does not 
open, hold the aluminum 
bell, rotate the black hand 
grip left or right, pull out the 
stop bolt and attempt to 
push down again.

Bulb does not light.

Power supply has incorrect 
voltage or frequency.

Check power supply.

Damaged or loose bulb.

Check bulb.

Loose plug.

Ensure that all plugs are 
properly seated and locked.

Faulty, damaged, or burned 
bulb socket.

Replace socket.

Faulty or damaged ballast.

Replace ballast.

Light shuts off and/or 
restarts during operation

Defective electrical net-
work.

Check power supply.

Deviation in frequency by 
more than ±10Hz.

Check power supply.

Light flickers during opera-
tion

Deviation in frequency by 
more than ±10Hz.

Check power supply.

Power supply unstable or 
insufficient.

Check power supply.

Generator’s condenser may 
be worn out.

Check generator.

Too many other machines 
using the same generator.

Check generator.

Содержание LB 1

Страница 1: ...Indirect Lighting System LB 1 OPERATOR S MANUAL 0163721en 003 0708 0 1 6 3 7 2 1 E N...

Страница 2: ......

Страница 3: ...ine 6 1 3 Guidelines for Service Safety 7 1 4 Labels 8 2 Operation 9 2 1 Intended Use 9 2 2 Setting up the Balloon 10 2 3 Setting up the Tripod 11 2 4 Assembling the Balloon to the Tripod 12 2 5 Turni...

Страница 4: ...reduce the risk of injury carefully read understand and observe all instructions described in this manual Wacker Neuson Corporation expressly reserves the right to make technical modifications even wi...

Страница 5: ...fety messages that follow this symbol DANGER indicates a hazardous situation which if not avoided will result in death or serious injury f Obey all safety messages that follow this symbol to avoid inj...

Страница 6: ...Clearly mark support ropes so that the support ropes do not pose a hazard for passersby Keep plugs and receptacles dry Keep a distance of at least one meter 3 feet between the balloon and any flammabl...

Страница 7: ...by a qualified technician Turn the machine off before performing maintenance or making repairs When maintaining this machine Never allow a machine with a known problem or deficiency to be operated Rep...

Страница 8: ...Safety Information LB 1 wc_si000219gb fm 8 1 4 Labels...

Страница 9: ...work areas The end user assumes all responsi bility for operating the machine safely and within its specified parameters Local regulations Consult with local authorities to determine regulations limi...

Страница 10: ...5 mm 0 20 in as the seals provide some resistance The balloon is fully expanded when the stop bolt clicks into the lowest tension posi tion 4 Check that the hook and loop Velcro seal is closed all ar...

Страница 11: ...ngth of the leg so that the mast is vertical 3 The mast should not touch the ground Adjust the mast so that it is at least 6 cm 2 inches from the ground 4 Adjust the braces b so that they are parallel...

Страница 12: ...e that each carabiner b moves freely and is not jammed 3 Each of the three support ropes c is provided with a loop on both ends Attach a support rope to each carabiner Let the free ends of the ropes h...

Страница 13: ...a suitable ground location and loop the free ends of the support ropes around them to anchor the machine Make sure that the ropes are taut The LB 1 is now ready for operation CAUTION Pinch point Fing...

Страница 14: ...tance at the capacitors the capacitor is discharged within a defined period of time approximately 30 seconds Turning off Follow the procedure below to turn off the light 1 Unplug the ballast from the...

Страница 15: ...is properly screwed into the socket Inspect the lower and upper covers for damage Do not operate the balloon with a defective cover Cleaning Follow the instructions below for cleaning the machine If...

Страница 16: ...he generator unplug the light and allow the bulb to cool at least 15 minutes 2 Remove the balloon from the tripod 3 Expand open the balloon See section Setting up the Balloon 4 Mount the balloon in a...

Страница 17: ...llation Follow the procedure below to install a new bulb 1 With a gloved hand screw the bulb into the light fixture NOTICE Avoid touching the bulb with your bare hands Oils from your skin may shorten...

Страница 18: ...r frequency Check power supply Damaged or loose bulb Check bulb Loose plug Ensure that all plugs are properly seated and locked Faulty damaged or burned bulb socket Replace socket Faulty or damaged ba...

Страница 19: ...Operation wc_tx000741gb fm 19 2 9 Electrical Schematic Ref Description Ref Description 1 Power source 5 Lamp 2 Power source plug and cord 6 Transformer 3 Ballast box 7 Capacitor 4 Ballast plug 8 16A...

Страница 20: ...inimum maximum m ft m ft 2 6 8 6 6 2 20 3 Weight kg lbs 21 46 3 Diameter mm in 900 35 4 Lamp type Metal halide Lamp output Watt 1000 Luminous flux lm 99 0000 AC voltage V 230 115 Starting current Amp...

Страница 21: ...that the construction equipment specified hereunder Category Light Balloon has been produced in accordance with the following standards 98 37 EG 2006 95 EG 2004 108 EG EN 55015 EN 61000 3 2 EN 61000...

Страница 22: ...0 Fax 49 0 89 3 54 02 3 90 Wacker Neuson Corporation P O Box 9007 Menomonee Falls WI 53052 9007 Tel 262 255 0500 Fax 262 255 0550 Tel 800 770 0957 Wacker Asia Pacific Operations Skyline Tower Suite 23...

Отзывы: