BA 357-00 * 3.0 * 35700_04_Inbetriebnahme_03.fm
4-53
Putting into operation 4
4.5
Putting the machine into operation
Important information before putting the machine into operation
WARNING
Accident hazard due to persons in the danger zone!
Serious injury or death can be caused by not staying clear of the danger
zone of the machine.
►
Ensure that no one is in the danger zone.
►
Stop all work movements immediately if
persons enter the danger zone.
►
Seal off the danger zone with barriers.
Preparations for putting into operation
1. Review
"Preparing Machine for Operation" checklist on page 4-47
.
2. Check to see that the motor isolating switch is turned off
– see "Motor isolating switch" on page 4-22
3. Check that the parking brake is actuated
– see chapter 5 “Parking brake” on page 5-6
4. As required, open the battery cover plate and connect the battery
connector (training required).
5. As required, close the battery cover plate and lock it
– see "Locking the-battery cover plate" on page 4-19
.
6. Adjust the operator seat to the operator seating position and weight
– see "Operator seat" on page 4-7
➥
All controls must be within easy reach.
➥
It must be possible to move the brake and accelerator pedals to
their limit positions.
7. Adjust the rearview mirrors
– see chapter 4 “Adjusting the mirrors” on page 4-16
8. Sit down on the operator seat.
9. Fasten your seat belt.
10.Check whether all additional control circuits are switched off
– see chapter 5 “Continuous operation of 3rd control circuit” on
page 5-44
.
11.Place switchable functions on the joystick into neutral
– see chapter 5 “Control lever (joystick) overview” on page 5-32
.
12.Set the low-speed control (opt) to “Maximum”
– see chapter 5 “Low-speed control with regulated travel speed (opt)”
on page 5-103
.
Содержание KRAMER 5055e
Страница 12: ...1 6 BA 357 00 3 0 35700_01_Vorwort fm 1 Preface Notes...
Страница 36: ...2 24 BA 357 00 3 0 Sicherheit_E fm 2 Safety Notes...
Страница 98: ...4 26 BA 357 00 3 0 35700_04_Inbetriebnahme_01 fm 4 Putting into operation...
Страница 103: ...BA 357 00 3 0 35700_04_Inbetriebnahme_02_a3 fm 4 31 Putting into operation 4 Switch panels Switch panels...
Страница 252: ...6 12 BA 357 00 3 0 35700_06_Transport fm 6 Transport Notes...
Страница 264: ...7 12 BA 357 00 3 0 35700_07_Wartung fm 7 Maintenance Maintenance label Affixed on the cabin...
Страница 340: ...7 88 BA 357 00 3 0 35700_07_Wartung fm 7 Maintenance Notes...
Страница 382: ...8 42 BA 357 00 3 0 35700_08_Betriebsst rung fm 8 Malfunctions...
Страница 408: ...9 26 BA 357 00 3 0 35700_09_Technische_Daten fm 9 Technical data...
Страница 416: ...S 8 BA 357 00 3 0 BA_35700_V3_enSIX fm Index...
Страница 417: ...BA 357 00 3 0 BA_35700_V3_enSIX fm S 9 Index...
Страница 418: ...S 10 BA 357 00 3 0 BA_35700_V3_enSIX fm Index...