Operation
GP/GPS 6600A
32
3.17 To Start
Before starting, be sure you read and understand all the safety and
operating instructions in this manual.
3.17.1
Ensure that the generator is properly installed in an outdoor location.
See Sections Installation and Operator Safety while using Internal
Combustion Engines for installation warnings and safety guidelines.
3.17.2
Disconnect all loads from the generator and place the main circuit
breaker switch in the OFF position (a2).
3.17.3
Set the auto idle switch to “OFF” (c).
3.17.4
Open the fuel valve (d1).
Note: If the engine is cold, move the choke lever to the closed position
(e2). If the engine is warm, set the choke lever to the open position
(e1).
3.17.5
On recoil start engines, turn the engine switch to “ON” (b1) and pull the
starter rope (f).
3.17.6
On electric start engines, press the ignition switch (k) and hold until the
engine starts. Release the switch after the engine starts.
NOTICE: DO NOT run the starter motor more than 5 seconds at a time
or damage to the starter motor may occur. If the engine fails to start,
release the switch and wait 10 seconds to let the starter motor cool
before trying again.
Note: If the oil level in the engine is low, the engine will not start. If this
happens, check the oil level and add oil as needed.
3.17.7
As the engine warms up, move the choke lever to the OPEN position
(e1).
3.17.8
Allow the engine to warm up for a few minutes before placing the main
breaker in the "ON" position (a1) and attaching loads.
Содержание CARB
Страница 1: ...Generator GP 6600A GPS 6600A CARB OPERATOR S MANUAL 0171950en 002 0609 0 1 7 1 9 5 0 E N...
Страница 4: ...wc_tx000001gb fm 4...
Страница 14: ...Safety Information GP GPS 6600A wc_si000239gb fm 14 2 5 Label Locations GND 88897...
Страница 23: ...GP GPS 6600A Operation wc_tx000791gb fm 23...
Страница 43: ...GP GPS 6600A Maintenance 43...
Страница 45: ...GP GPS 6600A Maintenance 45...