Technical data
40
14.5
Extension cable
Only use permitted extension cables, see chapter
Safety
.
Refer to the following table for the required cross-section area of the
extension cable:
Note:
Refer to the nameplate or the chapter
Technical data
(via the item
number) for the type designation and voltage rating of your machine.
WARNING
Electrical voltage.
Injuries from electrocution.
f
Check power cable and extension cable for signs of damage.
f
Only use extension cables for which grounded conductors are connected to
the plug and the coupling (only for machines of class rating I, see chapter
Technical Data
).
Machine
Voltage
[V]
Extension
[m]
Cross-section
area of cable
[mm
2
]
FUE 1/042/200W
FUE 1/120/200W
230 1
~
< 31
1,5
< 52 2,5
< 82
4,0
FUE 2/042/200W
FUE 2/250/200W
230 1
~
< 23
1,5
< 38
2,5
< 61
4,0
FUE 6/042/200W
FUE 6/042/
200W SC
FUE 6/042/
200W SC 4CEE
220-240 1
~
< 41
1,5
< 67
2,5
< 107
4,0
KTU 2/042/200W
KTU 2/250/200W
230 1
~
< 23
1,5
< 38
2,5
< 61
4,0
Содержание 0008884
Страница 1: ...Operator s manual Converter FUE KTU 03 2011 0227699en 002...
Страница 2: ......
Страница 44: ...15 Glossary 44...
Страница 46: ......
Страница 47: ......
Страница 48: ......