Technical Manual
WDGA with CANopen-Interface
6 - WDGA object dictionary
© Wachendorff Automation GmbH & Co. KG
29
Rev.1.24
Object
No.
Name
Sub
Idx
Function
Data type
ro
rw
co
Map
Default
value
2502h
Error History
00h Non-volatile error
history.
Unsigned32
co
no
dyn
01h Standard Error field 1 Unsigned32
ro
dyn
02h Standard Error field 2
Unsigned32
ro
dyn
03h Standard Error field 3
Unsigned32
ro
dyn
04h Standard Error field 4
Unsigned32
ro
dyn
05h Standard Error field 5
Unsigned32
ro
dyn
2503h
Alarms-
History
00h Logging of alarms
occurred.
Number of alarms.
Unsigned8
co
no
dyn
01h Alarm 1
Unsigned16
ro
dyn
02h Alarm 2
Unsigned16
ro
dyn
03h Alarm 3
Unsigned16
ro
dyn
04h Alarm 4
Unsigned16
ro
dyn
05h Alarm 5
Unsigned16
ro
dyn
2504h
Warnings-
History
00h Logging of warnings
occurred. Number of
warnings.
Unsigned8
rw
no
dyn
01h Warning 1
Unsigned16
ro
dyn
02h Warning 2
Unsigned16
ro
dyn
03h Warning 3
Unsigned16
ro
dyn
04h Warning 4
Unsigned16
ro
dyn
05h Warning 5
Unsigned16
ro
dyn
Table 6.12: manufacturer specific objects 2502h –2504h
(p. = page reference; ro / rw / co = access type; Map = PDO-Mapping; i* = individual;
dyn = dynamic; ST = singleturn; MT = multiturn)
Содержание WDGA CANopen
Страница 1: ...R e v 1...