Technical Manual
WDGA with CANopen-Interface
6 - WDGA object dictionary
© Wachendorff Automation GmbH & Co. KG
26
Rev.1.24
Object
No.
Name
Sub
Idx
Function
Data type
ro
rw
co
Map
Default
value
6335h
CAM6
hysteresis
00h Indicating the
hysteresis for the 6th
cam
Unsigned8
co
no
01h
01h Changing the
hysteresis for the 6th
cam
Unsigned32
rw
0000 0000h
6336h
CAM7
hysteresis
00h Indicating the
hysteresis for the 7th
cam
Unsigned8
co
no
01h
01h Changing the
hysteresis for the 7th
cam
Unsigned32
rw
0000 0000h
6337h
CAM8
hysteresis
00h Indicating the
hysteresis for the 8th
cam
Unsigned8
co
no
01h
01h Changing the
hysteresis for the 8th
cam
Unsigned32
rw
0000 0000h
6400h
Area state
register
00h Indicating if the
current position is in
or outside the work
area
Unsigned8
co
yes
01h
01h Status of the area
state register:
00h=within area;
03h=outside work
area
05h=outside work
area
Unsigned8
ro
dyn
6401h
Work area
low limit
00h Number of sub-
indices
Unsigned8
co
no
01h
01h Changing / Indicating
the work area low
limit
Signed32
rw
0000 0000h
6402h
Work area
high limit
00h Number of sub-
indices
Unsigned8
co
no
01h
01h Changing / Indicating
the work area high
limit
Signed32
rw
0000 4000h
6500h
Operating-
status
00h Indicates the
operating state of the
device
Unsigned16
ro
no
dyn
6501h
Measuring
units per
revolution
00h Indication of the
singleturn resolution
Unsigned32
co
no
0000 4000h
6502h
Number of
distinguish-
able
revolutions
00h Indication of the
multiturn resolution
Unsigned16
co
no
ST: 0001h
MT: FFFFh
6503h
p. 34
Alarms
00h Alarm set by
malfunction.
Unsigned16
ro
yes
dyn
6504h
Supported
alarms
00h Information about
supported alarms.
Unsigned16
co
no
0001h
Table 6.9: Device specific objects 6335h –6504h