5 Web server
5.1 General
The EtherCAT encoders have a web server where you can view or adjust information
and configurations. To reach the web server, call up its set IP address using a browser
of your choice (Internet Explorer, Firefox, etc.). To do this, connect the encoder via an
Ethernet cable (M12 plug to the encoder and RJ45 plug to the PC) to your computer.
Ensure that your PC is installed in the same IP address range as the encoder and that
TwinCAT is active.
Example configuration:
Encoder IP address:
192.168.1.127
PC IP address:
192.168.1.100
PC sub-net address:
255.255.255.0
Once you have done this, the encoder's start page opens (Information - Summary).
In the sub-sections below, we show you the various views of the web server and
explain the possible functions to you.