background image

INSTALLATION INSTRUCTION 

24VDC Dim-To-Warm POWER SUPPLY 

A2D50-60, A2D50-96 

 

waclighting.com 

Phone (800) 526.2588 

Fax       (800) 526.2585 

Headquarters/Eastern Distribution Center    

44 Harbor Park Drive  

Port Washington, NY 11050 

 

Central Distribution Center  

1600 Distribution Ct  

Lithia Springs, GA 30122  

Western Distribution Center 

1750 Archibald Ave  

Ontario, CA 91761  

 

 

  AiSPiRE retains the right to modify the design of our products at any time as part of the company's continuous improvement program

. March 2022      

1. 

 

 

 

SAFETY INSTRUCTION 

IMPORTANT: NEVER attempt any work without shutting off the electricity. 

  Always turn off power at fuse box prior to installation to prevent electrical shock.  

  For installation and serviced by a qualified, licensed electrician.  

  Install in accordance with national electric code, and local regulations.  

  Consult with local inspector to assure compliance. 

 

CAUTION 

  Read all instructions before installing.  

  Handle product with care. 

  Do not modify or disassemble product beyond instructions or warranty will be void. 

  Failure to follow safety warnings, and installation instruction will void the warranty 

  This power supply is designed to work with only AiSPiRE Dim-To-Warm tape light. 

 

FEATURES 

  Protection: short circuit/over loading/over temperature 

  24VDC Output, 4A Max (96W) & 2.5A Max (60W) Output Current on each output channel

, ≥

 0.9 pf 

  Ambient Temp: -20ºC to 45ºC (-4°F to 113°F) 

  Full protection aluminum housing for dry and damp location 

 

 

PRODUCT DIMENSION: 

 

60W & 96W  

 

 

 

 

 

 

Содержание AiSPiRE A2D50-60

Страница 1: ...r to installation to prevent electrical shock For installation and serviced by a qualified licensed electrician Install in accordance with national electric code and local regulations Consult with local inspector to assure compliance CAUTION Read all instructions before installing Handle product with care Do not modify or disassemble product beyond instructions or warranty will be void Failure to ...

Страница 2: ...f the tape run and make sure that it is under 100ft The allowed maximum distance of wires between the output of power supply to the beginning of tape is 100 ft The minimum output gauge wire of power supply is 20 AWG To extend the cable length if needed In Wall Rated Joiner Cable A2L02 and Joiner Cable Extender A2L01 WT can be used to join between sections as shown below To extend the cable length ...

Страница 3: ...e power supply must be installed away from any heat sources and it must be accessible for service Enclosed 24VDC Dim To Warm class 2 output remote power supply is UL listed The power supply box has a separate line voltage and low voltage wiring compartments Trade size knock out are provided on both compartments Connect building wires to the same color power supply wires with wire nuts or UL certif...

Страница 4: ...prings GA 30122 Western Distribution Center 1750 Archibald Ave Ontario CA 91761 AiSPiRE retains the right to modify the design of our products at any time as part of the company s continuous improvement program March 2022 4 SYSTEM DIAGRAM ON OFF Switch System ELV Dimmer Control System 0 10V Dimmer Control System CAUTION AISPIRE Dim To Warm Tape light may not be able to dim with other power supply ...

Отзывы: