WAC Lighting
www.waclighting.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. MArCh, 2016
INSTALLATION INSTRUCTION
InvisiLED® Electronic Remote Transformer
EN-OD24100-RB2-T
CAUTION – TO REDUCE RISK OF FIRE AND ELECTRICAL SHOCK
•
Read all instructions before installing.
•
System is intended for installation by a qualified electrician in accordance with the National Electrical Code and
local regulations.
•
Go to the main fuse box, or circuit breaker. Place the main power switch in the “OFF” position and unscrew the fuse(s) or switch “OFF”
the circuit breaker switch(es) that control the power to the fixture or room that you are working on.
•
Place the wall switch in the “OFF” position.
AVERTISSEMENT:
IMPORTANT : COUPEZ L’ÉLECTRICITÉ AVANT TOUTE MANIPULATION.
-
Lisez toutes les instructions avant d’installer.
-
Système est destiné à être installé par un électricien qualifié en conformité avec le code national de l’électricité et les règlements locaux.
-
Accédez au panneau central de disjoncteurs ou de fusibles de votre demeure et placez l’interrupteur principal en position d’arrêt (« OFF »).
-
Placez l’interrupteur mural en position d’arrêt (« OFF »).
HARDWARE:
Wire Connector
Qty: 3pcs
Cover Screw
Qty: 2pcs
Mounting Screw
Qty: 2pcs
24V Outdoor Tape Light
Female Connector
Qty: 1pc
MAX LOAD
96W
MIN LOAD
1W
INPUT VOLTAGE
120VAC 0.84A 50/60Hz
OUTPUT VOLTAGE
24.0VAC 4AMAX
AMBIENT TEMP
-20ºC TO 50ºC (-4°F TO 122°F)
INSTALLATION LOCATION
Damp location listed (Not wet location)
PRODUCT DIMENSIONS:
A1
B1
D1
1
8
”
4
”
Mounting
Holes
d
” Knockouts
6
2
”
E1
1
2
”