Page 39 of 62
POS-124-U-PFN-2030
Typical settings:
Command
Input
Description
AIN_1:X 1000 1000 0 V
0… 10 V
Range: 0… 100 %
AIN_1:X 10 8 1000 V
OR
AIN_1:X 1000 800 1000 V
1… 9 V
Range: 0… 100 %; 1 V = 1000 used for the offset and
gained by 10 / 8 (10 V divided by 8 V (9 V -1 V))
AIN_1:X 10 4 500 V
OR
AIN_1:X 1000 400 500 V
0,5… 4,5
V
Range: 0… 100 %; 0,5 V = 500 used for the offset and
gained by 10 / 4 (10 V divided by 4 V (4,5 V -0,5 V))
AIN_1:X 20 16 2000 C
OR
AIN_1:X 2000 1600 2000 C
OR
AIN_1:X 1250 1000 2000 C
4… 20mA
Range: 0… 100 %
The offset will be compensated on 20 % (4 mA) and the
signal (16 mA = 20 mA
– 4 mA) will be gained to 100 %
(20 mA).
Each of this parameterization for 4… 20 mA is setting the
range to 0… 100 %.
5.8
PROCESS DATA (Monitoring)
Command
Parameters
Unit
WA1
W1
X1
E1
V1
U1
ES
WA2
W2
X2
E2
V2
U2
External command position axis 1
Actual command position after ramp function axis 1
Feedback positon axis 1
Control error axis 1
Speed set point axis 1
Control signal axis 1
Synchronisation error
External command position axis 2
Actual command position after ramp function axis 2
Feedback positon axis 2
Control error axis 2
Speed set point axis 2
Control signal axis 2
mm
mm
mm
mm
%
%
mm
mm
mm
mm
mm
%
%
The process data are the variables which can be continuously observed on the monitor or on the oscillo-
scope.
Содержание POS-124-U-PFN
Страница 57: ...Page 57 of 62 POS 124 U PFN 2030 23 08 2016...
Страница 59: ...Page 59 of 62 POS 124 U PFN 2030 23 08 2016...
Страница 62: ...Page 62 of 62 POS 124 U PFN 2030 23 08 2016 10 Notes...