POS-124-U-PFN-2030
SSI:RES (Signal resolution)
Command
Parameters
Unit
Group
SSI:RES
X
x= 100… 10000
0.01 µm
INPUT
This command defines the signal resolution
3
of the sensor. Data entry has a resolution of 10 nm (nanome-
ters or 0.01 micron). If the sensor has one-micron resolution, the value must be set to 100. This makes it
possible to scale rotational sensors.
Take the data from the sensor data sheet.
SSI:BITS (Number of bits)
Command
Parameters
Unit
Group
SSI:BITS X
x= 8… 31
-
INPUT
With this command the number of data bits can be set.
Take the data from the sensor data sheet.
SSI:CODE (Signal coding)
Command
Parameters
Unit
Group
SSI:CODE X
x= GRAY|BIN
-
INPUT
With this command the signal coding can be set. Take the data from the sensor data sheet.
SSI:POL (Direction of the sensor signal)
Command
Parameters
Unit
Group
SSI:POL1 X
SSI:POL2 X
x= +|-
-
INPUT
To reverse the working direction of the sensor, with this command, the polarity can be changed.
3
The internal resolution of the controller is 1 µm. The sensor with better resolution should not be used without consulting
with the manufacturer.