Page 13 of 62
POS-124-U-PFN-2030
4 Technical description
4.1
Input and output signals
Connection
Supply
PIN 3, PIN 31 and
PIN 35
Power supply (see technical data)
PIN 4, PIN 32 and
PIN 36
0 V (GND) connection.
Connection
Analogue signals
PIN 11
0 V (GND), potential for analogue input signals, internally connected to PIN 4
PIN 12
0 V (GND), potential for analogue output signals, internally connected to PIN 4
PIN 13
Analogue position actual value (X1), signal
range 0… 10V or 4… 20 mA, scalable
PIN 14
Analogue position actual value (X2), signal
range 0… 10V or 4… 20 mA, scalbale
PIN 15 / 16
Valve control signal axis 1.
Type of signal and polarity can be selected by the parameter SIGNAL:U1.
PIN 19 / 20
Valve control signal axis 2.
Type of signal and polarity can be selected by the parameter SIGNAL:U2.
Connection
SSI sensors
PIN 33
Power supply for sensor 1
PIN 34
0 V (GND) for sensor 1
PIN 37
CLK +
PIN 38
CLK -
PIN 39
DATA +
PIN 40
DATA -
PIN 47
Power supply for sensor 2
PIN 48
0 V (GND) for sensor 2
PIN 41
CLK +
PIN 42
CLK -
PIN 43
DATA +
PIN 44
DATA -
Connection
Digital inputs and outputs
PIN 8
Enable input:
This digital input signal initializes the application. The signal will be approved in connection
with the software enable the corresponding axis.
PIN 1
READY output:
ON:
The module is enabled; there are no discernible errors.
OFF:
Enable is deactivated or an error has been detected.
Содержание POS-124-U-PFN
Страница 57: ...Page 57 of 62 POS 124 U PFN 2030 23 08 2016...