5.3.3
N_RANGE:X (Sensor nominal pressure)
Command
Parameter
Unit
Group
N_RANGE:X X
x= 10
… 1000
0
mm
IO_CONFIG
(EASY)
This command defines the nominal working range of the feedback sensor. Wrong parameterisation causes
wrong system settings. The control parameters cannot be calculated correctly in case of wrong values.
N_RANGE always has to be equal or higher than SYS_RANGE.
5.3.4
OFFSET:X (Sensor offset)
Command
Parameter
Unit
Group
OFFSET:X X
x= -10
0000…
100000
µm
IO_CONFIG
(EASY)
Adjustment of the zero point of the sensor.
5.4 Position Controller
5.4.1
VRAMP (Ramp time for external speed demand)
Command
Parameters
Unit
Group
VRAMP
x
x= 10… 5000
ms
CONTROL
The rate of change of the external speed demand can be limited by this ramp time.