Page 23 of 53
POS-123-P-PFN
5.2.7
POSWIN:S (Static position monitoring)
5.2.8
POSWIN:D (Dynamic position monitoring)
Command
Parameters
Unit
Group
POSWIN:S
x
POSWIN:D
x
x= 2… 200000
x= 2… 200000
µm
µm
SYSTEM
This parameter is entered in µm.
The POSWIN command defines a range for which the relating status message is generated. This function
monitors the deviation between the command and actual position. The positioning process is not influenced by
this function.
START must be activated to generate the messages.
POSWIN:S
Reporting reaching the target position with the parameterized accuracy.
POSWIN:D
Reporting continuously the actual deviation (following error in NC mode).
5.3 Input signal adaptation
5.3.1
SYS_RANGE (System stroke)
Command
Parameter
Einheit
Gruppe
SYS_RANGE x
x= 10… 10
000
mm
IO_CONFIG
This command sets the nominal working stroke which is 100 %. The axis can be moved via a set value specifi-
cation of 0 mm up to the position entered here. Wrong settings may lead to incorrect system settings and de-
pending parameters cannot be calculated correctly.
5.3.2
SIGNAL (Type of input signal)
Command
Parameters
Unit
Group
SIGNAL:X x
x=
OFF
U0-10
I4-20
U10-0
I20-4
-
IO_CONFIG
(EASY)
This command is used to define the type of the input signal (voltage or current) and to set the direction of the
signal. This is available for the analogue sensor input.