Page 21 of 53
POS-123-P-PFN
5.2 System parameters
5.2.1
MODE (Parameter view)
Command
Parameters
Unit
Group
MODE
x
x= SYSTEM|IO_CONFIG|
CONTROL|POWERSTAGE|ALL
-
-
This command changes the actual view on the parameter list. For a better overview only the parameters of the
selected group are displayed. Alternatively all active parameters can be shown.
5.2.2
LG (Changing the language)
Command
Parameters
Unit
Group
LG
x
x= DE|EN
-
SYSTEM
Either German or English can be selected for the help texts.
5.2.3
SENS (Malfunction monitor)
Command
Parameters
Unit
Group
SENS
x
x= ON|OFF|AUTO
-
SYSTEM
This command is used to activate/deactivate the monitoring functions (4… 20 mA sensors, output current,
signal range and internal failures) of the module.
ON:
All monitoring functions are active. Detected failures can be reset by deactivating the ENABLE
input.
OFF:
No monitoring function is active.
AUTO:
Auto reset mode. All monitoring functions are active. If the failure doesn’t exist anymore, the
module automatically resumes to work.
Normally the monitoring functions are always active because otherwise no errors are detectable via
the READY output. Deactivating is possible mainly for troubleshooting.