4.4.6 Parameter list
Command
Defaults
Unit
Description
196 -
Defining functionality
EN -
Changing language help texts
STD -
Parameter mode (standard or expert)
AUTO
Activation and deactivation of the monitoring functions
OFF -
Activation and deactivation of the characteristic linearization
OFF
OFF = Enable for both channels via PIN 15
0
0
0,01 %
0,01 %
Range of the input signal monitoring (e. g. detecting failures of joy-
sticks)
+
+
-
-
Changing output direction
V
V
-
-
Simple input switchover between current (4...20 mA) and voltage
(±10 V). Command is active if MODE = STD.
A: 1000
B: 1000
C: 0
X: V
-
-
0.01 %
-
Free scaling of the analogue input signal
100
100
ms
ms
Two quadrant ramp Channel A
100
100
ms
ms
Two quadrant ramp Channel B
X Y
X Y
-
-
Linearization function
0
0
0,01 %
0,01 %
Compensation of the dead band
10000
10000
0,01 %
0,01 %
Scaling of the max. output signal
200 0,01 %
Trigger point for activating the MIN value.
1000
1000
mA
mA
Nominal output current.
500
500
0,01 %
0,01 %
Dither amplitudes. Related to the nominal output current.
121
121
Hz
Hz
Dither frequency
2604
2604
Hz
Hz
PWM frequency
ON -
Automatic adjustment of PPWM and IPWM parameters
7
7
40
40
-
-
-
-
Parameters for the closed loop current controllers