Page 19 of 35
PAM-195-P-S3
5 Parameter
5.1
Parameter list
Group
Command
Default
Unit
Description
Basic parameters
LG
EN -
Changing language help texts
MODE
STD -
Parameter view
AINMODE
EASY -
Input scaling mode
SENS
AUTO -
Malfunction monitor
CCMODE
OFF -
Activation and deactivation of the characteristic linearization
SOLENOIDS
2 -
Number of solenoids
POL
+ -
Output polarity
Input signal adaptation
Command signal scaling
SIGNAL:W
U0-10 -
Type of input
AIN:W
A: 1000
B: 1000
C: 0
X: V
Free scaling of the analogue command signal input. Gets acti-
vated when AINMODE is switched over to MATH.
SYS_RANGE
100 bar
System pressure
Sensor signal scaling
SIGNAL:X
U0-10 -
Type of input
AIN:X
A: 1000
B: 1000
C: 0
X: V
Free scaling of the analogue feedback input. Gets activated
when AINMODE is switched over to MATH.
N_RANGE:X
100 bar
Sensor nominal pressure
OFFSET:X
0 mbar
Sensor offset
Ramp function
RA:1
RA:2
RA:3
RA:4
100
100
100
100
ms
ms
ms
ms
Command signal four quadrant ramp times
Power limitation function
PLV:A
PLV:B
10000
10000
0.01 %
0.01 %
Power limitation factor
PLT1:A
PLT1:B
5000
5000
0.1
ma
0.1 ms
Dynamic of the power limitation
Содержание PAM-195-P-S3