INSTALLATION INSTRUCTIONS AND SPECIFICATIONS

VEF2B/W/S MAGNUM ARCHITECTURAL  EXTERNAL FAN

•  Body components made from Powdercoated Aluminum construction. 
•  Accepts standard 150mm ducting.  
•  Supplied with terminal  box and motor capacitor. 
•  Grille Cover Depth – 75 mm.
•  5 Year Warranty
•  Available in: 

 

VEF2S - Exterior Extractor Fan with Stainless Steel Grille

 

VEF2W - Exterior Extractor Fan with White Grille

 

VEF2B – Exterior Extractor Fan with Black Grille

1.  Loosen the 4 x M6 cover screws holding on the cover and remove the cover by 

sliding it off the fan base assembly.

2.  Make a hole cut-out on the mounting surface that can accommodate spigot and 

electrical supply cable.

3.  From the above wiring diagram, wire Fan and capacitor inside to the terminal box.
4.  Securely seal the ducting to the spigot.
5. 

Mount the fan base assembly to the wall or soffit. Ensure terminal box and duct 

are placed inside the cut-out.

6.  Ensure the Fan is level before tightening screws. 
7.  Reinstall cover to the fan base assembly by securing 4 x M6 cover screws  

on both sides. 

FEATURES

INSTALLATION

An exterior mounted extract fan, ideal for bathrooms, laundries and drying rooms. 

Suitable for soffit or side wall mounting.

145.0

287.0

287.0

Appliance Class: Class I  

Voltage: 230 - 240Vac at 50/60 Hz

Power: 60W 

Operating Temperature: -20° C to +70°C

Number of Blades: 7 

RPM: 2490 RPM 

Water Ingress: IPX4

Climate Class: T

Duct Size: 150 mm 

Airflow: 582 m³/h (161.7 L/s) 

Air Pressure: 333.4 Pa at 50 Hz

SPECIFICATIONS

•  Appliance no

t intended for use by persons (including children) with reduced 

 

 

physical, sensory or mental capabilities, or lack of experience and knowledge,  

 

unless they have been given supervision or instruction concerning use of  

 

appliance by person responsible for their safety.

•  Children should be supervised to ensure they do not play with appliance.
•  Ensure that the fan is switched off from supply mains before moving the guard.
• Precaution

s must be taken to avoid back flow of gasses into room from open flue 

 

 

of gas or other fuel burning appliances (for duct and partition fans). 

•  If supply cord is damaged, it must be replaced by the manufacturer, its service  

 

agent or similarly qualified persons in order to avoid a hazard.

SAFTEY WARNING