VXI VT1509A Скачать руководство пользователя страница 1

Eight-Channel
Fixed Filter and Amplifier
Signal Conditioning Plug-on
VT1509A

User’s Manual

The VT1509A manual also applies to Agilent/HP E1413s as Agilent/HP E1413 Option 19.

Enclosed is the User’s Manual for the VT1509A Signal Conditioning Plug-on. Insert this
manual  in  your VT1413C and Agilent/HP E1313 manual behind the “Signal Conditioning
Plug-ons” divider.

bus

Manual Part Number:    82-0083-000

                                      Printed:  June 16, 2003

                                         Printed in U.S.A.

Copyright ©   VXI Technology, Inc., 2003

Содержание VT1509A

Страница 1: ...HP E1413s as Agilent HP E1413 Option 19 Enclosed is the User s Manual for the VT1509A Signal Conditioning Plug on Insert this manual in your VT1413C and Agilent HP E1313 manual behind the Signal Cond...

Страница 2: ......

Страница 3: ...d commands and explains the capabilities of this SCP Finally it covers specifications for this SCP The contents of this manual are Installation 3 Identifying the Plug on 3 Connecting To The Terminal M...

Страница 4: ...e stickers are as follows For VT1413C and above Terminal Modules use stickers for VT1509A SCPs The connections are shown in Figure 1 For Agilent HP E1313 Terminal Moduless use stickers for VT1509A SCP...

Страница 5: ...dule VT1509A Fixed Filter Amplifier SCP 5 Figure 2 VT1509A B size Terminal Module Connections Ch 00 31 Figure 3 VT1509A B size Terminal Module Connections Ch 32 63 Figure 4 Agilent HP E1413B Option 19...

Страница 6: ...s 0 through 7 send SYST CTYP 100 query SCP type ch 0 enter statement here Querying the Filter Cutoff Frequency While the the VT1509A does not provide programmable cutoff frequency the filter frequency...

Страница 7: ...8 enter statement here Detecting Open Transducers This SCP provides a method to detect open transducers When Open Transducer Detect OTD is enabled the SCP injects a small current into the HIGH and LO...

Страница 8: ...n the SCP The first channel on each SCP is 0 8 16 24 32 40 48 and 56 To enable Open Transducer Detection on all channels on SCPs 1 and 3 DIAG OTD ON 100 116 0 is on SCP 1 and 16 is on SCP3 To disable...

Страница 9: ...will be returned to the Query Response Register Detecting Open Transducers Open Transducer Detection OTD is controlled by bits in the Card Control Register For more information on OTD see Figure 1 Ca...

Страница 10: ...ired 200 to 850 C Resistance Opt 15 required 128W to 131 kW FS Strain 25 000 e or limit of linear range of strain gage Maximum input voltage Normal mode plus common mode Operating 16 V peak Damage lev...

Страница 11: ...cifications The temperature accuracy specifications include instrument and firmware linearization errors The linearization algorithm used is based on the IPTS 68 78 standard transducer curves Add your...

Страница 12: ...5 to 65 C 65 to 85 C OFF ON 0 0061 C 0 0055 C 0 011 C 0 010 C 100 W Reference RTD A D Filter 125 to 70 C OFF ON 0 080 C 0 080 C 100 W RTD A D Filter 200 to 75 C 75 to 300 C 300 to 600 C 600 to 970 C O...