background image

Instruction Manual INCU-Line Premium

 

Page 

37

 / 

61

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 
 
 
 

5.14. Types of accounts and their limits 

 

There are two different account types available. Each has its own qualities and limits described below. 

 

Admin account 

It has access to 

program management menu

, where you can create or edit programs (

programs

), check 

their statistics (

statistics and data register

) and information about the system (

info

). 

 

Confirms and saves the user 

 

Cancels the entered data and returns to the list of users. 

 

The device can have up to 5 users. There are 40 programs available that can be freely distribut-

ed among users.  

Figure 35 - User edition 

Содержание 390-1335

Страница 1: ...mium Cooled Incubators European Catalogue Numbers INCU Line 240CR PREMIUM 390 1335 INCU Line 150R PREMIUM 390 1338 INCU Line 400CR PREMIUM 390 1336 INCU Line 250R PREMIUM 390 1339 INCU Line 750CR PREMIUM 390 1337 Version 4 3 Issue 10 2021 ...

Страница 2: ...bility to correctly dispose of your equipment at lifecycle end by handling it over to an authorized facility for separate collection and recycling It s also your responsibility to decontaminate the equipment in case of biological chemical and or radiological contamination so as to protect from health hazards the persons involved in the disposal and recycling of the equipment For more information a...

Страница 3: ...Premium and IL 750CR Premium 13 5 UNIT OPERATION 14 5 1 Internal memory 14 5 2 First boot 14 5 3 Using the keypad 14 5 4 User logging in 15 5 5 Main Screen 16 5 5 1 Alarm bar 17 5 5 2 Alarms panel 17 5 5 3 Information panel 18 5 5 4 Status description 19 5 5 5 Status protection and alarms 19 5 6 Programs 20 5 6 1 Program creating edition 21 5 6 2 Segments edition 22 5 6 3 Summary of segments 24 5 ...

Страница 4: ...IL CR Premium 46 5 21 Corrections 47 6 COMPONENTS OF THE UNIT 49 6 1 Internal socket 49 6 2 Door lock 49 6 3 Access port 49 6 4 Open door alarm 50 6 5 Internal light internal LED light 50 6 6 USB port 51 7 TEMPERATURE PROTECTION 52 8 REMOTE CONTROL OF THE UNIT 52 9 OPERATION OF THE COOLING SYSTEM 53 10 CLEANING AND MAINTENANCE OF THE UNIT 54 10 1 Exterior cleaning 54 10 2 Interior cleaning 55 11 A...

Страница 5: ... or store humid samples if possible do not store warm samples secure samples from being blown out by the chamber fan e g powdery samples always check that the doors are closed use only earthed mains to avoid electric shocks unplug the power cable holding the protective cover and not the cable itself disconnect the unit from the mains before undertaking any repairs or maintenance works protect the ...

Страница 6: ...des 2 pcs each keys to the lock 2 pcs Manufacturer test certificate at 37 o C Ethernet cable Multilingual instruction manual and Premium Control Software can be downloaded from internal memory on the USB Stick Description Quantity Cat No Additional stainless steel shelf for IL 150 and IL 250 Premium 1 390 1340 Additional stainless steel shelf for IL 240CR Premium 1 390 0967 Additional stainless st...

Страница 7: ...mpliance with the above recommendations may result in damage to the unit or impair tech nical parameters The electric installation should meet the following conditions The electric installation should be secured by a 16 A antisurge fuse The IL 240CR IL 400CR and IL 750CR units are equipped with leveling castors After the unit has been placed in its destination lock the castors and level the unit u...

Страница 8: ...wing steps to adjust shelf height in IL 150R Premium and IL 250R Premium 1 Install the shelf bracket at the selected height by inserting it into appropriate slots on the chamber wall 2 Install the second shelf bracket on the opposite chamber wall 3 Slide the shelf into the shelf brackets 4 The shelf is now correctly installed 1 2 3 4 ...

Страница 9: ...e chamber wall 2 Install the second shelf bracket on the opposite chamber wall 3 Slide the shelf into the shelf brackets 4 The shelf is now correctly installed To remove a shelf perform the above steps in reverse order To remove the shelf holder from the slots lift it up and slide it towards the rear of the chamber 3 2 Condensation in the chamber Water may gather on the bottom of the chamber as a ...

Страница 10: ...cessary to adhere to the following rules the max height of the samples should not exceed 2 3 of the shelf space the samples should be placed so that the space between the containers does not exceed 1 3 of the width and height of the shelf samples should be placed with equal spacing between each other and the chamber walls The picture below is an example of the placement of samples in the chamber H...

Страница 11: ...dle to the vertical position push the door gently then turn the handle to the horizontal posi tion If the door has not been closed properly an alarm will sound Closing the door correctly reduces energy consumption and ensures consistent temperature variation and fluctuation 3 5 Internal glass door To open or close the internal glass door use the plastic handle installed on the glass While operatin...

Страница 12: ...ber fan 4 Access port 30 mm 5 Shelf 6 Height adjustable feet 7 Key lock 8 Internal electrical socket 9 Internal LED lighting 10 Temperature sensor 11 Main power socket 12 LAN 13 Main power switch 14 Condenser 15 Compressor 4 OVERVIEW 4 1 IL 150R Premium and IL 250R Premium 1 3 4 5 10 6 8 9 2 7 14 15 11 13 12 ...

Страница 13: ...h 7 touch panel 2 Access port 30 mm 3 Chamber fan 4 Shelf 5 USB port 6 Internal lighting 7 Temperature sensor 8 Castors 9 Main power switch 10 Main power socket 11 Fan cover 12 Cooling system 13 LAN 4 2 IL 240CR Premium IL 400CR Premium and IL 750CR Premium 8 1 2 3 4 5 7 6 13 ...

Страница 14: ...instruction manual on a USB stick Insert the USB Stick and wait a second to detect the hardware then press By pressing you quit downloading the folder the window will appear again during the next start You can tick Don t show again so that the window will not be dis played when you start You can always download the Download folder in the information panel More information page 38 5 3 Using the key...

Страница 15: ...cter Confirmation of the entered text closing the keypad 5 4 User logging in Only the logged in user can control the device If no user is logged in press in the main screen The login window will appear Figure 3 Login panel Factory default login parameters login admin leave the password field empty Sometimes input characters can be displayed as asterisks This happens when input information is secre...

Страница 16: ...o most functionalities the user should log in Figure 4 Main Screen Main Menu Start Stop the program Current temperature Set temperature to change press the icon or value for more information see page 30 Elapsed or remaining time of program to change press the icon or val ue for more information see page 31 Information panel four different windows to scroll slide to the right or left for more infor...

Страница 17: ...ith active alarm the control bar is red The alarm event is displayed in the list with the status alarm active When an alarm event stops the alarm remains in the list as inactive delete button confirms and removes the alarm from the list only inactive alarms can be deleted confirm button confirms the class 2 0 alarm details button displays a preview of all instances of selected alarm Figure 6 If th...

Страница 18: ... Closed door open door The number above the icon presents open door counter press the icon to cancel the counter The counter is also can celled during turning on the device Icon for the fan Rotating icon shows that the fan is running Icon does not move at status program off or when the fan is defect Ramp status Chamber is currently cooling down or heating up to reach set temperature Set temperatur...

Страница 19: ...urrent loop Currently performing cycle total number of cycles to perform page 26 status Status of the program ramp set temperature program off time set Set time of performing segment time elapsed Elapsed time after reaching the segment time remaining Remaining time until the end of the segment 5 5 5 Status protection and alarms In the left part there is information about the class and the upper an...

Страница 20: ...r and download it from the USB flash drive Menu push buttons Run the selected program Stop the program Add a new program Edit the selected program Delete the selected program Download the program from the USB flash drive Information about the number of created programs and the programs to be created is presented at the top A A Figure 10 List of programs Figure 9 Status protection and alarms ...

Страница 21: ...e program Segments number the number of segments Interval frequency of saving to data logging Protection class more information page 53 Protection temperature temperature range for the protection class Priority the priority of time or parameters more information page 26 Loop the number of program repetitions more information page 24 Cancels adding or editing of the program Switching to the edition...

Страница 22: ...erature protection 2 C time the time of maintaining the set temperature d hh mm days hours and minutes it is possi ble to select continuous work in the last segment ramp time the time of reaching the set temperature d hh mm days hours minutes fan fan efficiency in percent ramp fan fan efficiency during reaching the set temperature The active value is highlighted in blue The item highlighted in red...

Страница 23: ...hamber may frost temperature stability and uniformity will be affected and condensation may occur as a result With more parameters you can scroll the panel up and down The navigation between segments program parameters and summary is done by swiping up the segment with the finger or touch the icon Figure 14 Program segment edition Figure 15 Program segment edition ...

Страница 24: ...e if the number of segments is equal to 2 or more When the program finishes the last segment the device starts the program again from the first segment You can define if a program should be carried out once loop 1 or multiple times loop 2 to 255 You can also set the program to be carried out continuously tick the option If a cycle run is active after finishing the last segment the program will con...

Страница 25: ...sured by an independent temperature sensor the so called security sensor The main aim of the cartridge protection is to protect against uncontrolled rise or fall in temperature At the moment of activation the relay disconnects the heating cooling power supply Additionally the device is equipped with Class 3 3 over temperature protection when the temperature drops below the set protection value the...

Страница 26: ...ction temperature 50 C the maximum temperature set in the segment that can be given is 48 More information see page 53 5 7 Starting the program You can start the program in two ways The first way Press the icon programs in main menu Figure 18 Then select the program you want to activate and press Start button Figure 19 Figure 19 List of programs Figure 18 Main menu ...

Страница 27: ...l Figure 20 press the icon in the upper right corner Select the program you want to activate Figure 21 you have got two additional options Immediate start of the program Scheduled program start according to the set date and time Figure 20 Main screen Figure 21 Starting the program ...

Страница 28: ...selected by scrolling the list up or down Figure 22 Confirm the change by pressing Temperature cannot be lower than protection temperature under temperature 2 C and higher than protec tion temperature over temperature 2 C 5 8 2 Quick change the set time In order to quickly change the duration time of the program press the icon in main screen Figure 4 Select the number of days hours and minutes by ...

Страница 29: ...change of other parameters In order to quickly change of other parameters of the program press the icon in main screen Figure 4 Select the parameter you want to change and make changes by scrolling the list up or down Figure 24 Confirm the change by pressing Figure 23 Quick change of time Figure 24 Quick change of other parameters ...

Страница 30: ... C the highest recorded temperature Average temperature C average temperature Segment status of the segment In progress currently performed segment data is constantly updated finished the segment is made interrupted the segment was interrupted by the User before the set time expired Segment 1 2 the number of the currently overviewing segment number of the currently performed or completed segment N...

Страница 31: ... according to the selected column To do so click the column heading Data are only registered when the program is running The frequency of registration depends on the program parameters settings The time of opening the Data Register depends on the number of saved data The larger num ber of stored cells increases the opening time of the window Then a progress window will appear Figure 26 indicating ...

Страница 32: ...ith Super Admin rights can delete all data also those regis tered by other users Figure 28 5 10 1 Graph It is possible to generate a graph Figure 29 from the available samples in the data register Displays the entire graph back to the list of graphs Back to Data Register The time of opening the graph depends on the number of saved data The larger number of stored cells increases the opening time o...

Страница 33: ... back to the normal size of the graph 5 11 Event log The window displays information about registered events alarms and errors Data is only available for Super Admin users Saving the data onto USB flash drive csv files are available semicolon separated by opening e g with a spreadsheet plkx opening with the Premium Control applica tion Deleting data Figure 30 Enlarging the graph Figure 31 Event lo...

Страница 34: ...een restarted after power failure Program Start starting the program Program Stop stopping the program Under Protection Start sub temperature protection has been activated Under Protection Stop sub temperature protection has been finished Lower temp alarm Start lower temperature alarm has been activated Lower temp alarm End lower temperature alarm has been finished Upper temp alarm Start upper tem...

Страница 35: ...re and instruction manual on the USB memory stick write the service data on the USB stick contact the service for more information If an external storage is connected to the unit then during the entry to the Info panel the suggestion to save the unit configuration file on the USB stick appears Figure 33 The file is used to create an offline program in the Premium Control application Figure 33 Savi...

Страница 36: ...mber of created users the total number of users to create Available programs the total number of available programs to be assigned to users 5 13 1 User creating edition Press or and the panel with user data will appear Figure 35 Should be given login a user name password account password password confirmation enter the password again to confirm it type type of account Super Admin Admin more inform...

Страница 37: ...ount It has access to program management menu where you can create or edit programs programs check their statistics statistics and data register and information about the system info Confirms and saves the user Cancels the entered data and returns to the list of users The device can have up to 5 users There are 40 programs available that can be freely distribut ed among users Figure 35 User editio...

Страница 38: ...1 Super Admin account Super Admin account has not limits It has access to the program menu management and to the settings menu Figure 36 Main menu Admin Figure 13 Main menu Super Admin Figure 37 Main menu Super Admin Figure 38 Main menu Super Admin ...

Страница 39: ...nterface In this panel Figure 40 you can Change the language of device Set the time after which the screen will be dimmed Turn on off the sound alarm sounds will be still emitted Set the time after which the user will be automatically logged out Figure 40 Interface settings Figure 39 Main menu Super Admin ...

Страница 40: ...If you change the date and time to an earlier than the current one a message will appear on the display Changing the date time will interfere with the records in the database Delete the data from data record and event log first then change the date time You must first delete the data from the data record and from event log and then change the date time Confirms and saves changes Cancels the entere...

Страница 41: ...given in this field The lower and upper alarm can only be generated after reaching the set temperature delay exceed alarm the alarm will be activated with a delay 1 min 2 min 5 min 15 min after exceeding the permitted temperature delay door alarm the door alarm will be activated when the door is opened for the time selected by the user 5 s 30 s 1 min 5 min 10 min Confirms and saves changes Cancels...

Страница 42: ...r router s that manages the Ethernet network DNS IP address of the domain name system MAC the address of the network card read only DHCP you can select if the server that allocates IP addresses is running on the local network You can then skip setting IP Masks Gates Icon indicates the connection status Device connect Device disconnect Confirms and saves changes Cancels the entered changes Only one...

Страница 43: ... you can set the parameters needed to activate notifications via e mail The panel is divided into three windows Selection of event types for which notifications should be sent Figure 45 Activate activate or deactivate e mail notifications Door alerts alarms caused by the half open door Critical alerts critical alerts e g sensors damage Temperature alerts alarms caused by too high or too low temper...

Страница 44: ... the entered changes If you do not enable the activate option at the top of the panel emails will not be sent Sender and recipients Figure 46 Sender sender s e mail address Recipients recipient s e mail addresses up to 3 Figure 45 E mail events Figure 46 E mail sender and recipients ...

Страница 45: ...password SMTP Server Host SMTP Server Port SMTP You can also select the way of encryption TLS or SSL The above information can be obtained from the email account provider Connecting test Confirms and saves changes Cancels the entered changes Before testing the connection make sure that the device is connected to a computer net work and has a properly configured network connection Figure 47 E mail ...

Страница 46: ...aintained for 30 minutes If the defrosting function is active you will see the following icon on the main screen 5 20 2 Defrosting function only for IL CR Premium The panel Figure 49 allows to control the defrosting of interior of the device You can set Period h is counted when the temperature is lower or equal to 5 C for the set tempera ture and lower than or equal to 7 C for the current temperat...

Страница 47: ... 0 5 C The average temperature should be calculated from chosen period of time e g 30min The correction range of 5 C to 5 C The unit has been calibrated by the manufacturer in accordance with applicable norms The temperature shown on the display corresponds with a great accuracy to the temperature in the geometrical centre of the chamber For the correct operation of the unit it is not necessary to...

Страница 48: ...Instruction Manual INCU Line Premium Page 48 61 Confirms and saves changes Cancels the entered changes Figure 50 correction inputted by the User ...

Страница 49: ... working with electrical devices 6 2 Door lock All INCU Line units have been equipped with a door lock Depending on the model it may be located in the door handle or on the front panel 6 3 Access port A Ø30 mm access port can be used to insert an external temperature sensor which has been secured with a rubber plug The plug should cover the access port while the unit is operating If multiple cable...

Страница 50: ...t door open is displayed in the list with the status alarm active 6 5 Internal light internal LED light All incubators have been equipped with internal lighting which switches on when opening the door The IL 150R Premium and 250R Premium incubators come with LED lights Philips Corepro LEDspot 3 5 35W GU10 827 36D The IL 240CR Premium IL 400CR Premium and IL 750CR Premium come with oven lamp Amica ...

Страница 51: ... the device Go to Main Menu Data record press the button Select file type csv plkx Press Data is copied Data saved as csv file can be opened in the Notepad Data saved as plkx file can be opened only by Premium Control This program allows you f ex to view the data in the table as a graph It allows you to make a report of selected data range Figure 51 export saved data ...

Страница 52: ...s 3 3 according to DIN 12880 norm is called protecting sample function The User can set the temperature protection lower and upper limits by himself and when the set temperature falls outside of this range the power heaters or compressor is switched off When the temperature returns to within normal parameters the device continues to work normally 8 REMOTE CONTROL OF THE UNIT Every Premium unit can...

Страница 53: ... need to open the door and turn on the defrost function on the controller see chapter 5 20 If the unit works in a temperature below 8 C and the User does not defrost it periodically the compressor may overheat and break down 3 The device is equipped with a protection mechanism against damaging the cooling system The mechanism makes it impossible to turn on cooling when the temperature exceeds 45ºC...

Страница 54: ... recommend using cleaning solution to clean the stains which is dedicated to this particular application e g Pelox 10 1 Exterior cleaning 1 The housing and door should be cleaned with caution using a soft cloth dampened with water 2 Only mild cleaning products should be used to clean the device 3 Electrical parts should not be in contact with water or detergent 4 Clean the compressor and the evapo...

Страница 55: ...f any samples before cleaning 2 Open the door of the device and wait for the frost to melt take out the shelves and start cleaning the device 3 Only water or mild detergent should be used 4 Having finished cleaning you should allow the device to dry completely 5 During cleaning pay attention not to damage the temperature sensor in the chamber 11 ADVICE ON HOW TO SAFELY STORE THE UNIT 1 Remove all ...

Страница 56: ... the voltage in the socket Measure the voltage in the socket if necessary change the fuses in the electric instal lation in the building Check if the unit is plugged in Plug in the unit Check the fuse of the unit Press the fuse Check if the power cable is broken Change the cable The unit is not cooling down Check if the evaporator is dirty Clean the evaporator Check if the unit is exposed to direc...

Страница 57: ... to the manuals and any local regulations such warranty turns invalid except to the extent the defect of the product is not due to such non performance Items being returned must be insured by the customer against possible damage or loss This warranty shall be limited to the aforementioned remedies IT IS EXPRESSLY AGREED THAT THIS WARRANTY WILL BE IN LIEU OF ALL WARRANTIES OF FITNESS AND IN LIEU OF...

Страница 58: ...roduct identification label is located on the left upper corner of the unit An example of the product identification label 1 Logo 2 Type of the unit 3 Catalogue number 4 CE mark 5 Name and address of the manufacturer 6 Serial number 7 Bar code 8 UKCA mark and UK Importer 1 2 3 4 5 6 7 8 ...

Страница 59: ...Instruction Manual INCU Line Premium Page 59 61 15 TECHNICAL DATA ...

Страница 60: ...Instruction Manual INCU Line Premium Page 60 61 ...

Страница 61: ...Orion Business Campus Northwest Business Park Ballycoolin Dublin 15 Tel 353 01 88 22 222 Email sales ie vwr com Italy VWR International S r l Via San Giusto 85 20153 Milano MI Tel 39 02 3320311 Email info it vwr com Korea VWR International 17 Daehak 4 ro Yeongtong gu Suwon si Gyeonggi do Tel 82 31 645 7256 saleskorea avantorsciences com Middle East Africa VWR International FZ LLC DSP Laboratory Co...

Отзывы: