FULL SIZE ELECTRIC CONVECTION OVENS - TROUBLESHOOTING
F25105 (Rev. A, October 2007)
Page 58 of 60
Error Codes
In the display window, the error code will alternate between the code and the oven cavity temperature or dashes if
the oven is calling for heat (heat light on). The exact error code displayed will depend on the priority assigned to
the problem in the EPROM'S software. The lower the error code number, the higher the priority. If more than one
problem occurs at the same time, the error code assigned to the higher priority problem will be displayed. Refer to
the error code table below to solve the problem. If the lower priority problem still exists, the next error code will be
displayed. When the condition causing the error is resolved, normal oven operation can resume.
NOTE:
To check a "Setup Parameter" and its corresponding "Data Value", see SETUP MODE under COMPUTER
CONTROL.
NOTE:
If the cause of the error is not apparent, check for these conditions as they may also cause errors to occur:
Electrical noise or a noise event, excess environmental moisture or temperature, or vibration.
CODE & PROBLEM
PROBABLE CAUSE
SOLUTION
Er01 - ROM checksum error
Internal ROM malfunction
Cycle power
Er02 - RAM checksum error
Internal RAM malfunction
Cycle power
Er03 - Ambient sensor error
Ambient temperature is below 32
E
F
Check ambient temperature at the
control.
Er04 - Configuration error
Microprocessor malfunction
Cycle power
Er05 - EPROM error
1
Power loss while storing data
Cycle power
Er06 - Zone 1 A/D underflow error
• Incorrect sensor type
• Measuring temperature outside
the sensor range
• Check the InP1 setup parameter.
Verify it matches your sensor.
• Check sensor and connections
for a reversed or open sensor. If
the condition causing the error is
resolved, the error will clear.
Er07 - Zone 1 A/D overflow error
Open sensor
• Check the InP1 setup parameter.
Verify it matches your sensor.
• Check sensor and connections
for a reversed or open sensor. If
the condition causing the error is
resolved, the error will clear.
Er10 - Stack overflow error
Microprocessor malfunction
• Cycle power
• Check sensor and connections
for a reversed or open sensor
Er11 - Open sensor error
Open sensor
• Check the InP1 setup parameter.
Verify it matches your sensor.
• Check sensor and connections
for a reversed or open sensor
Er12 - Shorted sensor
• Incorrect sensor type
• Measuring temperature outside
the sensor range
• Check the InP1 setup parameter.
Verify it matches your sensor.
• Check sensor and connections
for a reversed or open sensor
NOTE:
1. Should only see when a new EPROM is installed and powered for the first time.
Содержание VC4EC
Страница 45: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 45 of 60...
Страница 47: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 47 of 60...
Страница 49: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 49 of 60...
Страница 51: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 51 of 60...
Страница 53: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 53 of 60...
Страница 55: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 55 of 60...
Страница 59: ...FULL SIZE ELECTRIC CONVECTION OVENS TROUBLESHOOTING F25105 Rev A October 2007 Page 59 of 60 N O T E S...
Страница 60: ...FULL SIZE ELECTRIC CONVECTION OVENS F25105 Rev A October 2007 Printed in U S A...