FULL SIZE ELECTRIC CONVECTION OVENS - SERVICE PROCEDURES AND ADJUSTMENTS
F25105 (Rev. A, October 2007)
Page 19 of 60
A.
Turn the power switch OFF.
B.
Install a replacement thermostat and check
calibration.
SOLID STATE TEMPERATURE
CONTROL TEST
1.
Remove the right side panel as outlined under
COVERS AND PANELS in REMOVAL AND
REPLACEMENT OF PARTS.
NOTE:
If right side panel is not accessible, this
component can be serviced by removing the control
panel as outlined under COVERS AND PANELS.
2.
Place a thermocouple in the geometric center of
the oven cavity.
NOTE:
Oven temperature must be below 450°.
3.
Set the temperature control to the maximum
setting.
4.
Check machine data plate for correct voltage to
oven. Refer to diagram below for proper
terminal locations and voltages before checking
the control. Use the correct terminals for the
corresponding voltage.
5.
Turn the power switch to ON.
6.
Check for proper voltage across terminals 8 &
10 (208-240VAC) for power to the control.
A.
If correct, proceed to step 7.
B.
If incorrect, problem is not with the
temperature control. See
TROUBLESHOOTING.
7.
Check relay voltages on the board:
A.
For 208-240VAC controls - check across
terminals 7 & 10 for input to the internal
relay and 6 & 10 for output from the
internal relay.
1)
If input voltage to the internal relay is
correct, proceed to step 8. If input
voltage to the internal relay is not
present, problem is not with the
temperature control. See
TROUBLESHOOTING.
2)
If output voltage from the internal
relay is correct proceed to step 8. If
output voltage from the internal relay
is not correct, check temperature
probe as outlined under
TEMPERATURE PROBE TEST
(SOLID STATE CONTROL).
8.
Set the temperature control to the minimum
setting.
NOTE:
Oven temperature must be above 300°F.
9.
Check for zero (0) volts AC across terminals 6 &
10 (208-240VAC) for no output from the internal
relay.
A.
If correct, temperature control is
functioning properly.
B.
If incorrect, check temperature probe as
outlined under TEMPERATURE PROBE
TEST (SOLID STATE CONTROL).
1)
If temperature probe is ok:
a.
Turn the power switch OFF.
b.
Replace the temperature control
and check calibration as outlined
under SOLID STATE
TEMPERATURE CONTROL
CALIBRATION.
Содержание VC4EC
Страница 45: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 45 of 60...
Страница 47: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 47 of 60...
Страница 49: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 49 of 60...
Страница 51: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 51 of 60...
Страница 53: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 53 of 60...
Страница 55: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 55 of 60...
Страница 59: ...FULL SIZE ELECTRIC CONVECTION OVENS TROUBLESHOOTING F25105 Rev A October 2007 Page 59 of 60 N O T E S...
Страница 60: ...FULL SIZE ELECTRIC CONVECTION OVENS F25105 Rev A October 2007 Printed in U S A...