background image

FULL SIZE ELECTRIC CONVECTION OVENS - SERVICE PROCEDURES AND ADJUSTMENTS

F25105 (Rev. A, October 2007)

Page 17 of  60

SERVICE PROCEDURES AND ADJUSTMENTS

 

Certain procedures in this section require electrical test or measurements while power is

applied to the machine. Exercise extreme caution at all times. If test points are not easily accessible,
disconnect power and follow lockout / tagout procedures, attach test equipment and reapply power to
test.

SOLID STATE TEMPERATURE

CONTROL CALIBRATION

1.

Place a thermocouple in the geometric center of
the oven cavity.

2.

Set the power switch to ON.

3.

Set the temperature control dial to 350 °F.

4.

Allow the oven temperature to stabilize
(normally 3 cycles).

5.

Record the temperature at which the Heat lamp
goes OFF and comes ON for at least two
complete heating cycles.

6.

Calculate the differential by subtracting the
temperature indicated when the lamp goes out
from the temperature indicated when the lamp
comes on.

A.

The differential calculated should be less
than 20 °F.

1)

If the differential is 20 °F or less, the
temperature control circuit is
functioning properly.

a.

Proceed to step 7.

2)

If the differential is more than 20 °F:

a.

Check the temperature probe as
outlined under "TEMPERATURE
PROBE TEST (SOLID STATE
CONTROL)".

b.

If the probe is functioning
properly then temperature control
is malfunctioning.

a)

Install a replacement
temperature control and
check calibration.

7.

Calculate the average temperature by adding
the temperature indicated when the lamp goes
out to the temperature indicated when the lamp
comes on and dividing this answer by 2.

A.

If the average temperature is 10 °F or 
less, from the dial setting, the thermostat is
properly calibrated.

B.

If the average temperature is more than 
10 °F from the dial setting, the thermostat
calibration must be adjusted.

1)

Loosen the temperature control knob
set screw and remove the knob from
the stem.

2)

Loosen temperature control mounting
screws only enough to rotate the
control.

a.

Place thumb and forefinger on
the head of the mounting screws,
apply pressure and slightly rotate
the screw heads (body of control)
in the slot. Rotate clockwise to
increase temperature and
counterclockwise to decrease.

b.

Center the stem in the opening
and re-tighten the temperature
control mounting screws.

c.

Replace knob and re-tighten set
screw.

d.

Rotate the knob to the lowest
temperature setting then back to
350°F.

e.

Repeat the average temperature
calculation in step 7.

Содержание VC4EC

Страница 1: ...a Vulcan Service School for this product you should read in its entirety the repair procedure you wish to perform to determine if you have the necessary tools instruments and skills required to perfo...

Страница 2: ...neous Doors 13 Roller Latch Assembly 14 Door Catch Roller Assembly Independent Doors 14 Mechanical KX Thermostat 15 High Limit Thermostat 15 Interior Lights 16 Cooling Fan 16 SERVICE PROCEDURES AND AD...

Страница 3: ...with Mechanical KX Controls 208 240V 37 VC4ES VC6ES with Mechanical KX Controls 480V 38 VC4ED VC6ED with Solid State Temperature Control 208 240V 39 VC4ED VC6ED with Solid State Temperature Control 4...

Страница 4: ...ultaneous doors are optional with or w o window 2 Stainless steel doors w o window standard 3 Stainless steel doors with window standard 4 In February 2001 this model was discontinued INSTALLATION Ref...

Страница 5: ...40 20 NOTES 1 Amperage values in the table are nominal Tolerance is 5 10 2 Complied in accordance with National Electric Code ANSI NFPA 70 latest edition MODEL TOTAL POWER KW AMPERAGE 1 PHASE 60HZ PER...

Страница 6: ...all Control Panel 1 Remove three 3 screws on the right side which secure the control panel then pull the panel away from the oven NOTE If the oven has a mechanical KX type thermostat it must be remove...

Страница 7: ...control panel 2 Remove the seven screws securing the left side panel 3 Pull the left side panel out at the bottom then down to remove 4 Reverse the procedure to install CONTROL PANEL COMPONENTS Remov...

Страница 8: ...ect the wire leads to the component being replaced 3 Remove the component 4 Reverse the procedure to install the replacement component and check oven for proper operation TEMPERATURE PROBE SOLID STATE...

Страница 9: ...e it difficult to remove elements thru the cavity A serial number cut off will not be available Follow the procedures for element removal as outlined below Front Access 1 Remove the oven racks and rac...

Страница 10: ...he heating element terminals through the top Once unstacked follow the removal procedure below 1 Perform steps 1 thru 4 under FRONT ACCESS 2 If the element is on the left side A Remove the left side p...

Страница 11: ...e 9 Position the replacement motor on the motor mounting plate and install mounting bolts and washers Hand tighten mounting bolts only 10 Reconnect lead wires at the motor replace conduit and junction...

Страница 12: ...dge of the door 3 Simultaneous doors A If replacing window on the left door remove the handle from the front of the door then remove door seal from the inside edge of the door 1 Lift out the inner doo...

Страница 13: ...ccessible for inspection and or replacement if needed A If bearings are ok proceed to step 8 B If replacing the top bearing remove the top bearing retainer and top bearing C If replacing the bottom be...

Страница 14: ...e of the turnbuckles 3 Loosen the set screw on the sprocket of door being replaced 4 Drive out the spirol pin from the sprocket of door being replaced 5 Remove the door from lower sill bearings and sp...

Страница 15: ...rd the probe should not extend beyond the guard 4 Remove the thermostat bulb from the oven cavity by pushing it through the oven wall and into the control panel area NOTE The hole in the oven cavity w...

Страница 16: ...lace by the retaining tabs 7 Install the light bulb and lens 8 Check for proper operation COOLING FAN 1 Remove the right side panel as outlined under COVERS AND PANELS NOTE If right side panel is not...

Страница 17: ...7 2 If the differential is more than 20 F a Check the temperature probe as outlined under TEMPERATURE PROBE TEST SOLID STATE CONTROL b If the probe is functioning properly then temperature control is...

Страница 18: ...fferential is 30 F or less the thermostat is functioning properly a Proceed to step 7 2 If the differential is more than 30 EF the thermostat is malfunctioning a Install a replacement thermostat and c...

Страница 19: ...tep 7 B If incorrect problem is not with the temperature control See TROUBLESHOOTING 7 Check relay voltages on the board A For 208 240VAC controls check across terminals 7 10 for input to the internal...

Страница 20: ...1 332 475 266 340 1 041 Resistance in ohms 10 HEATING ELEMENT TEST The following steps require power to be applied to the unit during the test Use extreme caution at all times 1 Turn the power switch...

Страница 21: ...lts 3 Adjust the motor position until the blower is parallel to and 1 4 inch away from the motor mounting plate Check for squareness of the blower to the motor mounting plate at the top bottom left an...

Страница 22: ...made after 8 12 07 and serial number starting with 54 made after 8 26 07 1 Remove top front cover as outline under COVERS AND PANELS in REMOVAL AND REPLACEMENT OF PARTS 2 Open the doors and inspect do...

Страница 23: ...th the doors closed observe the position of the catch roller ball in relation to the door strike A Ensure the catch roller ball is centered left to right to the door strike 1 Adjust alignment if neces...

Страница 24: ...s come together the right door will lead the left door in closing by about 1 4 inch The doors will feel like they are self closing the last 1 2 inch of travel Procedure 1 Remove the lower sill cover a...

Страница 25: ...ess the Rack 1 key a final time to exit the setup mode and return to operations mode The current set point temperature will be displayed After 1 minute of no key activations the control will return to...

Страница 26: ...2 A If voltage is correct SSR is functioning properly B If no voltage is present on the load side of SSR terminal 2 the SSR is not functioning properly 7 Turn the power switch OFF 8 Replace the SSR an...

Страница 27: ...Restore Factory Settings option is available The calibration mode contains several adjustable parameters that must not be changed For the CALY Calibration Parameter the default data option selected mu...

Страница 28: ...0 If pressed again advances to the next test B If the code displayed is not correct for the key pressed then the keyboard is malfunctioning 1 Turn the power switch OFF C Replace the computer control a...

Страница 29: ...by removing power from the heating circuit Auto resets at 500 F Computer Control Monitors temperature sensor and regulates the oven cavity temperature by controlling 2CON to energize the heating eleme...

Страница 30: ...ol board The probe is an RTD resistance temperature detector of the Thermistor type As temperature increases the resistance value decreases On oven models using the computer control the probe is a J t...

Страница 31: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 31 of 60 VC4ES 6ES with Mechanical KX thermostat Plug Socket and Components...

Страница 32: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 32 of 60 VC4ED 6ED with Solid State Control Plug Socket and Components...

Страница 33: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 33 of 60 VC4EC 6EC Plug Socket and Components Cook Hold Standard...

Страница 34: ...on VC4ED VC6ED with Solid State Temperature Control Schematic diagram 6534 will be used to explain the electrical sequence of operation Cook Cycle 1 Conditions A Oven connected to correct voltage and...

Страница 35: ...OFF or ON position VC4EC VC6EC Computer Control Schematic diagram 6536 will be used to explain the electrical sequence of operation or both the Cook cycle and the Cook and Hold cycle Cook Cycle 1 Cond...

Страница 36: ...m pins C2 2 and C2 8 is de activated and SSR1 relay is de energized 1 Power is removed from convection fan motor high speed terminal B The computer control 5VDC output from pins C2 1 and C2 8 is activ...

Страница 37: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 37 of 60 SCHEMATICS VC4ES VC6ES with Mechanical KX Controls 208 240V...

Страница 38: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 38 of 60 VC4ES VC6ES with Mechanical KX Controls 480V...

Страница 39: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 39 of 60 VC4ED VC6ED with Solid State Temperature Control 208 240V...

Страница 40: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 40 of 60 VC4ED VC6ED with Solid State Temperature Control 480V...

Страница 41: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 41 of 60 VC4EC VC6EC Computer Control 208 240V Roast Hold Standard...

Страница 42: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 42 of 60 VC4EC VC6EC Computer Control 480V Roast Hold Standard...

Страница 43: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 43 of 60 THIS PAGE PURPOSELY LEFT BLANK...

Страница 44: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 44 of 60 WIRING DIAGRAMS VC4ES VC6ES with Mechanical KX Control 208 240V...

Страница 45: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 45 of 60...

Страница 46: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 46 of 60 VC4ES VC6ES with Mechanical KX Control 480V...

Страница 47: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 47 of 60...

Страница 48: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 48 of 60 VC4ED VC6ED with Solid State Temperature Control 208 240V...

Страница 49: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 49 of 60...

Страница 50: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 50 of 60 VC4ED VC6ED with Solid State Temperature Control 480V...

Страница 51: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 51 of 60...

Страница 52: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 52 of 60 VC4EC VC6EC Computer Control 208 240V Roast Hold Standard...

Страница 53: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 53 of 60...

Страница 54: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 54 of 60 VC4EC VC6EC Computer Control 480V Roast Hold Standard...

Страница 55: ...FULL SIZE ELECTRIC CONVECTION OVENS ELECTRICAL OPERATION F25105 Rev A October 2007 Page 55 of 60...

Страница 56: ...otor inoperative Blower motor doesn t run in Cool Down but runs ok in ON position 1 Power switch S1 malfunction 2 Fan speed switch S3 malfunction 3 Interconnecting wiring malfunction Excessive or low...

Страница 57: ...justment or broken independent doors 4 Door seals damaged COMPUTER CONTROL MODELS ONLY SYMPTOM POSSIBLE CAUSES Oven does not heat 1 High limit switch open 2 Temperature probe malfunction 3 Computer co...

Страница 58: ...2 RAM checksum error Internal RAM malfunction Cycle power Er03 Ambient sensor error Ambient temperature is below 32EF Check ambient temperature at the control Er04 Configuration error Microprocessor m...

Страница 59: ...FULL SIZE ELECTRIC CONVECTION OVENS TROUBLESHOOTING F25105 Rev A October 2007 Page 59 of 60 N O T E S...

Страница 60: ...FULL SIZE ELECTRIC CONVECTION OVENS F25105 Rev A October 2007 Printed in U S A...

Отзывы: